Cleaning the platen
Clean the platen with a soft cloth.
Intervals and Materials for Cleaning
Clean inside the printer in accordance with the following:
Ribbon Cartridge
The inked ribbon in the cartridge is a continuous loop and will print several
million characters before needing replacement. When printed characters begin to appear feint, it
is time to replace ribbon cartridge.
Replacing the ribbon is a simple matter of taking out the old cartridge and replacing it with a new
one. Before removing the old cartridge always turn off the power and allow the print head to cool,
as it can be extremely hot. Then slide the print head to the left edge to avoid damage to the print
head cable. See the ribbon installation section in Chapter 2 for details.
Problems And Solutions
The following are some of the common problems, which you may encounter when using the
printer. By implementing the solutions suggested, you should be able to resolve them.
Printer is “Dead” No Light, No Action
Make sure that it is plugged in, check both ends of the
power cable. Make sure the power switch is turned on. Test the socket with another appliance to
make sure it is working, check the fuse in the plug attached to the power cable. Take your printer
to your dealer to be serviced.
Printer Won’t Work
Be sure that the printer cable is plugged into both the printer and the
computer. Make sure that there is paper inserted and the
ONLINE LED
is on.
Printing is Feint
Be sure that the ribbon cartridge is installed correctly. It must be fitted securely
into place and the ribbon must pass between the print head and the ribbon mark. Adjust the gap
adjust lever (move it upward). Replace the ribbon. Replace the print head.
NOTE
Over-application of oil may cause a build up of dust and dirt with resulting printer
failure.
NOTE
Intervals cleaning: Every 6 months or 300 hours of operation.
(Whichever comes first)
Materials:
Dry cloth (gauze or soft cloth)
Summary of Contents for FB 390
Page 1: ...SEIKO Precision FB 390 Dot Matrix Flatbed Printer USER MANUAL ...
Page 41: ......
Page 42: ......
Page 43: ......
Page 44: ......
Page 45: ......
Page 46: ......
Page 47: ......
Page 48: ......
Page 50: ...Company name SEIKO PRECISION Europe GmbH Address Hermann Buck Weg 9 D 22309 Hamburg Germany ...