Seiki ULA-25GSC Instruction Manual Download Page 3

WARNING 

 

CAUTION 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cares for Safety

 

Our company thinks it important to give priority to safety all the time in regard to shutter systems

to which our operator is applied as well as the operator.  
We ask you please to take ample measures and cares toward the shutter system and the environment around
it so that danger may be avoided not only when the shutter operates but also even should the shutter not
work normally. 
Shown below are “warning” and “caution” in selecting and using the operator as well as its peripheral

  equipment, and so never fail to follow them.  

 

Please abide by the following matters so that danger may be prevented. 

●In designing and installing a motor-driven shutter, read the catalog and the instruction manual carefully 

 to use it properly. 

●This operator is the one used exclusively for motor-driven shutters. 

Never use it for other applications.  

●Since the installing work of this operator includes work and skill requiring the qualification of 

an electrician, let the shutter electrician do installing work.  

・If this is not followed, the operator does not work properly or the shutter breaks down, thus sometimes 
 resulting in a vital accident. 

●As for the bracket, use the one designated by our company.  

・The operator does not function normally or as the case may be the shutter breaks down, thus sometimes 
 leading to a vital accident. 

●Firmly set the bracket in a correct position on structural members, refering to the shutter layout 

(installation drawing).

 

  ・The bracket is saddled with the total weight of the shutter. 
   Unless it is mounted firmly, the shutter breaks down, thus sometimes resulting in a vital accident. 
●Install the operator where it is not exposed to water or rain. 
  ・If this is not followed, it may sometimes cause a fire or electric shock. 
●Never fail to do grounding work for the operator. 
  ・If this is not followed, it may sometimes cause a fire or electric shock. 
●The operator should not be dismantled or modified. 

And any other parts should not be mounted than the option parts designated by our company. 

  ・There occurs a malfunction, which may sometimes cause injury.  
●In opening and closing the shutter, ensure that there are no human access or obstacles. 
  Never fail to show this warning to the caretaker of the shutter.  
  ・If one is sandwiched, it may sometimes cause injury.  
●For a pushbutton switch, select a keyed type. 
  ・If the shutter is operated by other person(a child etc.) than the caretaker, it sometimes causes one 

 to be sandwiched and injured.  

●Never fail to use the commercial power source. 

Let the supply voltage be within the designated voltage of the operator. 
・The operator breaks down, thus sometimes resulting in a fire or electric shock. 

 

Please abide by the following matters to prevent an accident. 

●Be sure to keep the power supply within the range of specified voltage in the operator.  

・Otherwise the operator may be damaged, and then it may cause a fire or electrical shock. 

●The size and weight of the shutter should fall within the application scope of the operator.  

・It is possible that the operator does not work properly or ,as the case may be, breaks down, thus resulting 
 in injury. 

●In operating the short link handchain, ensure that the shutter stops, and never operate 

 the pushbutton switch. 

  Never fail to show this caution explicitly to the caretaker of the shutter. 
  ・The short link handchain gets pulled in, whereby the operator may  sometimes break down. 
●When you operate the gravity fall lever, ensure that the shutter stops, and never operate the pushbutton 

 switch. 

  Never fail to show this caution explicitly to the caretaker of the shutter. 
  ・There occurs a malfunction, thereby the operator may sometimes break down.  
●Set the limit switch properly, and after it is set never fail to check on the motion and stop position 

 of the shutter. 

●Inspect the operator periodically, and if there is anything wrong, make repair or replacement.  
  Make periodic checks according to the opening & closing frequency or within the period of use stated 

 in the「

 Inspection on p.17」of this Instruction Manual. 

●There is a case in which even if the power source is shut off (the breaker is dropped etc.) while the 

 shutter is descending. 

At this time, the shutter stops at the lower limit. 

 

Shows that if there is anything wrong with installation work and handling of the 
product, you are likely to suffer death or serious injury. 

Shows that if there is anything wrong with installing work or handling of the  
product, you are likely to suffer slight injury or physical damage.

 

P1 

Summary of Contents for ULA-25GSC

Page 1: ...UTTER OPERATOR WITH BUILT IN SENSING MECHANISM ULA 25GSC RECEIVER LESS SPECIFICATION ULA 25GSCR RADIO RECEIVER BUILT IN TYPE Single phase 220 230V A REQUEST Be sure to check the contents in this instr...

Page 2: ...Obstacle Sensing Function upon Descent P6 Obstacle Sensing Function upon Ascent P6 Upper and Lower Limit Output Changeover P6 Motion Frequency Display P6 Installation of Operator P7 Connection P8 Ins...

Page 3: ...there are no human access or obstacles Never fail to show this warning to the caretaker of the shutter If one is sandwiched it may sometimes cause injury For a pushbutton switch select a keyed type I...

Page 4: ...cent less than 1W upon rated load descent Since speed is controlled slow start slow stop upon the start stop of motion better ability of calm sound has been realized than conventional products A stabl...

Page 5: ...r upper lower limit output specification only See on page 6 for Upper lower limit output changeover and 4 on page 9 for the connection Details of operation part See on page 5 for right left setting ch...

Page 6: ...ery life About a year in case of 10 times of use in a day Operating temp range 0 50 Operational humidity range Up to 85 RH without condensation Code setting 16 777 216 types set in manufacture Transmi...

Page 7: ...n it up so that there be no gap between brake housing and motor when pressing brake release lever And also tighten up 2 fixing screws along each diagonal line in order The operator is shipped in the e...

Page 8: ...p by the dip switch In case of not needing the function change the sensing power over to OFF Upon shipping the sensing power is set up to ON The load sensitivity upon ascent is a fixed value Obstacle...

Page 9: ...fore installing a winding drum never fail to hang roller chain on the teeth of drum sprocket Changeover between Right hand and Left hand Side Settings should be reversed before the operator See on pag...

Page 10: ...on page 8 page 9 for each connection 1 Connection of pushbutton switch and counter 2 Connection of emergency switch auxiliary limit switch 3 Connection of tape switch 4 Connection of upper lower limit...

Page 11: ...on of Upper Lower Limit Output for only the specification with upper lower limit output Take off the blue and transparent protection film from the connective part for upper lower limit output and turn...

Page 12: ...times then the buzzer sounds for 5 seconds thus upper limit being set Thereafter the shutter begins to descend while sounding the buzzer When Stop button is pressed during motion of no limit is set up...

Page 13: ...upper limit is reset When Press And Hold Operation is made with push button switch fine adjustment may be made easily When pressing Stop button of push button switch or Stop button of transmitter 5 ti...

Page 14: ...he operation of pushbutton switch or transmitter let the shutter ascend or descend to the lower limit you desire to change When lower limit you want to reset is lower than lower limit set at present l...

Page 15: ...e handchain hang and pull slowly the handchain farther from slat the shutter becomes released depending on the amount of pull When manual opening is made upon power failure let the shutter move to low...

Page 16: ...upon power failure never fail to move the shutter to lower limit When a power failure has recovered and shutter stops at the position except for a lower limit point power failure restoration mode will...

Page 17: ...y turns to normal mode Then the LED of transmitter goes off 2 Registration method 2 remote registration When the registration is completed press Register Delete All switch on the control panel once Th...

Page 18: ...r goes off 2 Deletion method 2 Separate deletion When the deletion is completed the buzzer stops sounding and the receiver automatically turns to normal mode After completion make sure that the receiv...

Page 19: ...ter Handling of transmitter Regular check This product is precision equipment Handle it with great care Do not subject the transmitter to strong impact drop on rigid floor or impact Otherwise it may c...

Page 20: ...stored when you operate pushbutton switch or transmitter abnormality display is cancelled automatically Unless the operator gets restored normally because of the above abnormality contact the supplier...

Page 21: ...d buzzer sounds when the shutter moves When guide rail etc are deformed heavily which may cause the shutter to be wound reversely never make descend motion Operator cannot be operated with pushbutton...

Reviews: