10. COIN SELECTOR
Turn the power for the machine OFF. Open the
coin chute door.
Remove the coin selector from the coin chute door.
Open the gate and dust off by using a soft brush
(made of wool, etc.).
Remove and clean smears by using a soft cloth
dipped in water or diluted chemical detergent and
then squeezed dry.
Remove the CRADLE.
When removing the retaining ring (E ring), be very
careful so as not to bend the rotary shaft.
Remove stain from the rotary shaft and shaft
receiving portions by wiping off with a soft cloth,
etc.
After wiping off as per above, further apply
a dry cloth, etc. to cause the coin selector to dry
completely.
CLEANING THE COIN SELECTOR
COIN INSERTION TEST
Once every month, when performing the
Coin SW Test, simultaneously check the
following:
Remove and clean smears by using a soft
cloth dipped in water or diluted chemical
detergent and then squeezed dry.
Never apply machine oil, etc. to the Coin
Selector.
After cleaning the Coin Selector, insert a
regular coin in the normal working status
and ensure that the Selector correctly func-
tions.
FIG. 13 a
FIG. 13 c
GATE
Insert a coin
while
keep-
ing the Reject
Button pressed
down and check
if it is rejected.
COIN METER
If the coin is not rejected when the REJECT button is pressed, open the coin chute door and open the
selector gate. After removing the jammed coin, put a normal coin in and check to see that the selector
correctly functions.
HANDLING THE COIN JAM
The coin selector should be cleaned once every 3 months.
When cleaning, follow the procedure below:
Does the Coin Meter count satisfactorily?
Does the coin drop into the Cashbox correctly?
Is the coin rejected when inserted while keeping the
Reject Button pressed down?
STOP
IMPORTANT!
1
2
3
4
7
6
5
5