46
3.16. TROUBLESHOOTING
·
Only QUALIFIED SERVICE PERSONNEL should carry out these procedures.
If a problem occurs, first check the wiring connections.
PROBLEMS
CAUSE
COUNTERMEASURES
When the main switch
is turned ON, the
machine is not
activated
The power is not ON.
Firmly insert the plug into the outlet.
Incorrect power source/voltage.
Make sure that the power supply/voltage
are correct.
AC Unit CIRCUIT PROTECTION
DEVICE (i.e. fuse) was activated due to
an instantaneous overcurrent.
First, remove the cause of overcurrent and
reinstate the circuit protection device to its
original status.
Then identify the cause of the fault on the
item which caused the overcurrent & fix.
The colour image on
the screen is incorrect
Incorrect monitor adjustment.
Make appropriate adjustments.
SEE SECTION 6.3.8.
The on-screen image
of the monitor sways
and/or shrinks
The power source and voltage are not
correct.
Make sure that the power supply and
voltage are correct.
Sound is not emitted
Sound volume adjustment is not correct. Adjust the volume setting on the VTS
bracket. SEE SECTION 6.2
Malfunctioning BD and Amp.
Perform Sound Test to check it. SEE
SECTION 6.3.7
Connector connection is incorrect
Check connector connection from Base to
Speaker
Controller operation is
not satisfactory
Sighting is inaccurate due to
environmental conditions, etc.
Adjust the gun sighting alignment. SEE
SECTION
Error! Reference source not
found.
Micro-switch malfunctioning
Replace the micro-switch. SEE SECTION
3.11
Sensor BD is malfunctioning
Replace the Sensor BD. SEE SECTION
3.11
The fluorescent lamp
does not light up
Fluorescent lamp needs replacement
Replace the fluorescent lamp. SEE
SECTION 3.13.1
The connector is disconnected
Check connector connections in the
billboard case.
Summary of Contents for Virtua Cop 3
Page 12: ...9 ...
Page 36: ...33 Actual machine may differ slightly from illustration ...
Page 48: ...45 3 15 COMPOSITION OF THE GAME BOARD ...
Page 87: ...84 9 PARTS LIST 9 1 VCT 10002UK ASSY CABINET VCT U R ...
Page 90: ...87 9 2 VCT 11002UK ASSY FRAMEWORK VCT U R ...
Page 114: ...LOCATE A3 SCHEMATIC DRAWING 1 HERE ...