86
COIN HANDLING
12
Credit Board
Service Button
Channel 1
CN3
SW3
Status LED
DIP SW 1
Channel 2
CN5
This product comes equipped with a Crane NRI Coin Acceptor. To adjust the price of play ALL
credit setting are adjusted via the EXCEL CREDIT BOARD.
IMPORTANT!
The CREDIT SETTINGS within the SYSTEM TEST MODE must be set to 1 coin 1 credit to allow the
CREDIT BOARD to function correctly.
The CREDIT BD has a built in accumilator. This is controlled by 2 DIL Switches. These allow the
operator to select the price of play, type of coin acceptor and region.
EXCEL Credit Board
12-3 ADJUSTING THE PRICE OF PLAY (EXCEL)
DIL SW3 (Regional Settings)
Adjust these switches to specify the type of Coin Acceptor used and currency.
Default = SW1&SW2 ON - SR3/NRI in parallel mode, Sterling.
SERVICE BUTTON
Provides a SERVICE CREDIT when pressed
Status LED
Flashes when functioning.
CHANNEL 1
To Coin Acceptor (SR3 TYPE.)
DIL SW1 (credit settings)
Adjust to required price of pay.
VOL CONTROL
MAIN VOLUME ADJUSTMENT (FRONT SPEAKERS)
● The price of play is determined by the configuration of switches located
on either an EXCEL board or VTS board. The type of board used is determined
by product location. Switch settings for both types of board remain the same.