54
COIN HANDLING
12
If the coin is not rejected when the REJECT button is pressed, open the coin chute door and open the selector gate.
After removing the jammed coin, put a normal coin in and check to see that the selector correctly functions.
The Coin Selector should be cleaned once every 3 months.
When cleaning, follow the procedure below:
12-1 FIG 1
● Remove and clean smears by using a soft cloth dipped in water or diluted
chemical
detergent and then squeezed dry.
● Never apply machine oil, etc. to the Coin Selector.
● After cleaning the Coin Selector, insert a regular coin in the normal
working status and ensure that the selector correctly functions.
12-1 CLEANING THE COIN SELECTOR
GATE
Handling the Coin Jam
12
COIN HANDLING
1
2
3
Turn the power for the machine OFF. Open the Coin Chute Door
Remove the Coin Selector from the Coin Chute Door
Open the gate and dust off by using a soft brush (Small soft Paint Brush, etc.)