15
TROUBLESHOOTING
98
Steering (Servomotor)
is weak in its force
feedback
Ageing of the force feedback
mechanism
Reset in the Test Mode.
Does not accept input in
from the Reset Button
unit.
Faulty connector or connections.
Check the connections between the I/O
Board, the Cabinet and the Reset Button
Unit
Faulty Microswitch
Replace Microswitch
T h e a c c e l e r a t o r o r
brake does not perform
appropriately.
Incorrect volume setting.
Adjust the volume value in the Test
Mode.
Faulty Volume attachment or adjust
gear alignment.
Adjust the volume attachment and verify
in Test Mode.
Faulty connector or connections.
Check the connections for the accelerator
and brake connectors and the connectors
between the accelerator, brake and
cabinet.
Failure of the volume.
Replace the volume.
Start button and View
Change button input
does not work and they
do not flash.
Faulty connector or connections.
Check the connections for the connectors
between the I/O Board, the cabinet and
the control panel and those inside the
control panel.
Start button and View
Change button input
works, but they do not
flash.
Unverified settings or operation.
The Start button only flashes when Free
Play is set. Check the operation in Test
Mode.
The lamp is blown.
Replace the lamp.
Failure of the network
play.
Network play is wrongly set.
Reset correctly.
C o m m u n i c a t i o n c a b l e s a r e
disconnected.
Communication cables are wrongly
connected.
Reconnect the cables.
Damage of communication cables.
Replace the cables. Contact the company
from whom the unit was purchased.
Summary of Contents for Grid 42
Page 9: ......
Page 90: ...COIN HANDLING 81 12 STERLING PRICE OF PLAY SETTINGS SW1...
Page 91: ...82 COIN HANDLING 12 EURO PRICE OF PLAY SETTINGS SW1...
Page 121: ...112 PARTS LIST 19 1 ASSY TOP GRID 42 RD 0008UK D 1 2 3 5 1 6 7 8 10 11 13 14 18 20...
Page 145: ......
Page 146: ...136 WIRING DIAGRAMS 21 D 1 3...
Page 147: ...137 WIRING DIAGRAMS 21 D 2 3...
Page 148: ...138 WIRING DIAGRAMS 21 D 3 3...