33
3.14. FUSES
•
Never touch places other than those specified. Touching places other than
those specified can cause electric shock and short circuit. Disconnect the
machine from the supply before attempting the replacement of any fuse.
•
Only QUALIFIED SERVICE PERSONNEL should replace FUSES.
•
Only replace fuses with ones of the same value and type.
There are a number of fuses used on this machine to protect the user and the machine from damage. Only
replace the fuse once you have removed the cause of its failure. Detailed below is a list of the fuses used,
their location and if relevant PCB reference:
PART NUMBER
LOCATION
TYPE & DETAILS
QTY
514-5078-3150
STEREO AMP REF. F1, F2 5x20mm CERAMIC SB 3.15A
2
514-5078-4000
SWITCH REG REF. F1
5x20mm CERAMIC SB 4A
1
514-5078-5000
IEC INLET REF. F1
5x20mm CERAMIC SB 5A
1
514-5078-6300
CONN. BD. REF. F1
5x20mm CERAMIC SB 6.3A
1
There are also fuses located on the Monitor PCB. Refer to the monitor manufacturer for further
information.