background image

SEG Electronics GmbH 

DOK-HB-CSPFHPTE 

Retrofit Kit for the Replacement of System Line CSP2-F by HighPROTEC MCA4 

Requirements 

This product manual assumes that System Line devices be replaced by HighPROTEC devices. 

 

WARNING 

 

Please read the present application description and all other publications that 
need to be consulted for working with this product (especially for installation, 
operation or maintenance). Observe all applicable safety regulations and 
warnings. 

Failure to follow the instructions may result in personal injury and/or 
damage to the product. 

Any unauthorized modification or use of this device beyond the specified 
mechanical, electrical or other operating limits may result in personal injury 
and/or damage to the product. 

Any such unauthorized modification constitutes "misuse" and/or "negligence" in 
the sense of the warranty for the product; this excludes the warranty for the 
coverage of possible damages resulting therefrom, and cancels product 
certifications and/or listings. 

 

CAUTION 

 

This document may have been revised or updated since this copy was made. To 
ensure that you have the latest revision, please refer to the download area of 
SEG Electronics GmbH: 
 

https://docs.SEGelectronics.de/csp 

 

 

Summary of Contents for CSP2-F

Page 1: ...CES BY HIGHPROTEC DEVICES Original document English Revision A ASSEMBLY INSTRUCTIONS AND INSTALLATION GUIDE PROTECTION TECHNOLOGY MADE SIMPLE CSP2 F MCA4 RETROFIT KIT FOR THE REPLACEMENT OF SYSTEM LINE DEVICES BY HIGHPROTEC DEVICES System Line HighPROTEC ...

Page 2: ... avoided could result in death or serious injury CAUTION CAUTION with a warning symbol indicates a dangerous situation which if not avoided may result in moderate or minor injury NOTE NOTE is used to highlight information that is not related to injury WARNUNGRNING Only to be carried out by qualified personnel If the devices are operated by inadequately qualified personnel there is a justified risk...

Page 3: ...result in personal injury and or damage to the product Any unauthorized modification or use of this device beyond the specified mechanical electrical or other operating limits may result in personal injury and or damage to the product Any such unauthorized modification constitutes misuse and or negligence in the sense of the warranty for the product this excludes the warranty for the coverage of p...

Page 4: ... in the HighPROTEC series The HighPROTEC devices offer more communication options protection and monitoring functions at a significantly lower price In addition these devices offer more possibilities for error analysis disturbance recorders NOTICE The CSP2 has several control outputs with separate power circuit for direct control of switching devices These are no longer available with HighPROTEC d...

Page 5: ...SEG Electronics GmbH DOK HB CSPFHPTE 5 Retrofit Kit for the Replacement of System Line CSP2 F by HighPROTEC MCA4 Hardware Structure of Terminal Strips CSP2 F ...

Page 6: ...6 Retrofit Kit for the Replacement of System Line CSP2 F by HighPROTEC MCA4 Hardware Structure of Terminal Strips MCA4 The figure shows a possible example variant the available variants are shown in the order code Typecode MCA4 see page 15 ...

Page 7: ... strip MCA4 Power supply X4 X1 Digital Inputs DI X3 X1 X5 X6 Signalling relay BO X6 X2 X5 X6 Phase current measurement X2 X3 Phase voltage measurement X5 X4 Self monitoring X6 Relais K11 X104 IRIG B X15 X104 Control interface X9 X10 X11 X103 Optical fiber interface X7 X102 Ethernet RJ45 interface N A X100 Grounding PE X4 X1 Power outputs control circuits XA1 X1 N A see the note in section General ...

Page 8: ...ew Device Software CSP2 F MCA4 The CSP2 F works with the System Line software the MCA4 works with the Smart view software Although these are two different user programs care has been taken to ensure that the structure tree is basically structured in the same way Simple parameterization of the new MCA4 protective devices ...

Page 9: ...ring the Remodeling on Site 1 Disassembly of the CSP2 F Label the plugs of the CSP2 F and the plugs base unit mounting plate This helps to assign the connectors later Only remove the individual cables from the plug terminal strip after checking with a continuity tester that you have removed the correct cable Remove the CSP2 F from the mounting plate ...

Page 10: ...it Kit for the Replacement of System Line CSP2 F by HighPROTEC MCA4 2 Disassembly of the Control Unit CMP1 Remove the CAN bus cable from the control unit Remove the power supply grounding cable Remove the control unit from the control cabinet door ...

Page 11: ... for the Replacement of System Line CSP2 F by HighPROTEC MCA4 3 Fasten the Adapter Plate Fasten the adapter plate in the control cabinet door using the washers and screws supplied No drilling or sawing required See the dimension drawing on the next page ...

Page 12: ...SEG Electronics GmbH DOK HB CSPFHPTE 12 Retrofit Kit for the Replacement of System Line CSP2 F by HighPROTEC MCA4 Adapter Plate HPT Catalog article identifier of the adapter plate CSPHPTADAP ...

Page 13: ...larger cable duct is recommended Start the rewiring on the door side device side The cables of each module should be connected to a string by cable ties The strings must be clearly marked Install an additional empty conduit so that the complete wire harness can be safely routed into the medium voltage cell Feed the cable harnesses through the empty conduits into the MS cell Wiring of the HighPROTE...

Page 14: ...in the HighPROTEC series Otherwise it is important to adjust the number of inputs and outputs of the old wiring with the new devices For example the complete System Line devices had a very large number of digital inputs These can be covered by selecting the appropriate hardware variant of the MCA4 Note that some information is no longer exchanged via digital inputs but via communication protocols ...

Page 15: ...urrent 5A 1A 0 Phase Current 5A 1A Sensitive Ground Current 5A 1A 1 Mounting form Housing suitable for door mounting A Housing suitable for 19 rack mounting B Communication Without communication protocol A RS 485 Modbus RTU IEC 60870 5 103 DNP3 RTU B Ethernet Modbus TCP DNP3 UDP TCP IEC 60870 5 104 C Fiber Optics Profibus DP D D SUB Profibus DP E Fiber Optics Modbus RTU IEC 60870 5 103 DNP3 RTU F ...

Page 16: ...SEG Electronics GmbH DOK HB CSPFHPTE 16 Retrofit Kit for the Replacement of System Line CSP2 F by HighPROTEC MCA4 Back View MCA4 for an example typecode MCA4 2D0ACA example device variant ...

Page 17: ...SEG Electronics GmbH DOK HB CSPFHPTE 17 Retrofit Kit for the Replacement of System Line CSP2 F by HighPROTEC MCA4 Back View CSP2 F ...

Page 18: ...Electronics GmbH DOK HB CSPFHPTE 18 Retrofit Kit for the Replacement of System Line CSP2 F by HighPROTEC MCA4 Photos from Practice System in original condition exterior view View of the cable bushing before ...

Page 19: ...SEG Electronics GmbH DOK HB CSPFHPTE 19 Retrofit Kit for the Replacement of System Line CSP2 F by HighPROTEC MCA4 System Line CMP1 operating unit dismounted ...

Page 20: ...SEG Electronics GmbH DOK HB CSPFHPTE 20 Retrofit Kit for the Replacement of System Line CSP2 F by HighPROTEC MCA4 Main unit CSP2 F System Line dismounted ...

Page 21: ...SEG Electronics GmbH DOK HB CSPFHPTE 21 Retrofit Kit for the Replacement of System Line CSP2 F by HighPROTEC MCA4 Equipment after remounting HighPROTEC MCA4 interior view ...

Page 22: ...en SEG Electronics GmbH Krefelder Weg 47 D 47906 Kempen Germany Postfach 10 07 55 P O Box D 47884 Kempen Germany Telephone 49 0 21 52 145 1 Internet www SEGelectronics de Sales Telephone 49 0 21 52 145 331 Fax 49 0 21 52 145 354 E mail info SEGelectronics de Service Telephone 49 0 21 52 145 614 Fax 49 0 21 52 145 354 E mail info SEGelectronics de Complete address phone fax email information for al...

Reviews: