6
1
Safety
Ausgabe
issue
D / 29.04.09
Dokument
document
OM.SAF.02e
Blatt
sheet
2 (4)
Height of
the danger
area
a
Height of the protective structure b
1)
1000
1200
1400
3)
1600
1800
2000
2200
2400
2600
2700
Horizontal distance to the danger area c
2700
2)
-
-
-
-
-
-
-
-
-
-
2600
900
800
700
600
600
500
400
300
100
-
2400
1100
1000
900
800
700
600
400
300
100
-
2200
1300
1200
1000
900
800
600
400
300
-
-
2000
1400
1300
1100
900
800
600
400
-
-
-
1800
1500
1400
1100
900
800
600
-
-
-
-
1600
1500
1400
1100
900
800
500
-
-
-
-
1400
1500
1400
1100
900
800
-
-
-
-
-
1200
1500
1400
1100
900
700
-
-
-
-
-
1000
1500
1400
1000
800
-
-
-
-
-
-
800
1500
1300
900
600
-
-
-
-
-
-
600
1400
1300
800
-
-
-
-
-
-
-
400
1400
1200
400
-
-
-
-
-
-
-
200
1200
900
-
-
-
-
-
-
-
-
0
1100
500
-
-
-
-
-
-
-
-
1)
Protective structures less than 1000 mm in height are not included, because
movement is not satisfactorily restricted.
2)
If the danger area represents a minor risk, the height h of the danger area must
be 2500 mm or more.
If the danger area represents a high risk, then
•
either the height h of the danger area must be 2700 mm or more
•
or other technical safety measures must be used..
3)
Protective structures below 1400 mm should not be used without additional
technical safety measures. (Source: DIN EN ISO 13857)
G
S
B
a
b
c
S
c
a
b
G
G
AST
a