29
9. Dismantling/Reassembly of the pump
D / 26.10.2017 - OM.MAI.84EN - 1/6
9.
Dismantling/Reassembly of the pump
9.1
Prepare pump for dismantling
Empty pipelines.
Allow pipelines to cool.
Remove pipeline connections (suction side/pressure side).
Observe de-commissioning instructions (
chapter 6).
9.1.1
Dismantle pump
9.1.2
Dismantle pressure branch (700)
DANGER
Risk of fatal injury from electrical current.
There is an immediate danger of fatal electric shock through contact with live
parts.
Note safety regulations.
Disconnect motor from all sources of energy.
Secure electrical connections against restarting.
Risk of injury due to lack of stability of
pump. Crushing of body parts due to the pump or
pump parts tipping or falling down.
Design with base plate
Fasten base plate
(GPU)
to secure pump.
–
Recommendation: Fasten to suitable base
using a screw fitting
(SCH)
.
Design without base plate
Fasten lantern
(200)
to secure the pump.
–
Recommendation: Fasten to suitable base
using a screw fitting
(SCH)
.
Support stator
(601)
with support
(S)
.
Dismantle screw fitting
(604, 606, 609)
.
Remove pressure branch
(700)
, trestles
(607,
704)
and tie bolts
(602)
.