Cut a piece slightly longer than this value and connect to the analyzer. Move the Marker 1 to the
point where <Zs (or Xs) crosses zero. In this case this frequency point is at 16.399 MHz.
Select
«MARK 1»
«Info».
The readings show a length of 3.016m and a length difference (M1-
M2) of 0.543m, which is the excess length of the piece of coax cable. Cut a piece slightly
shorter than this value and repeat the process until getting to the expected value.