S-Series
5 Operation
15
5.5.6
Utility Page
1
Information field about operating hours, serial number, loudspeaker library version, hard-
ware and firmware version. Loudspeaker libraries with version numbers ending in a 1 (e.g.
x.x1) contain phase linearization and time alignments. Version numbers ending in a 0 (e.g.
x.x0) do not include these features and are therefore compatible with HDLM8 and self-
powered speaker systems. The latest versions can be found in the download area of the
SEEBURG website.
2
Menu bar for calling up the Snapshot, Amplifier, Password, Ethernet and Reset tabs
3
Dimmer: Setting the brightness of the display
4
AutoDIM: Setting the waiting time until the display is automatically dimmed. The amplifier
remains in operation (operating mode button lights up green). As soon as the encoder is
operated, the display is switched on again.
5
AutoSLEEP: Setting the waiting time until the power amplifier automatically switches to
sleep mode. In Sleep mode, the amplifier channels are disabled. The sleep mode is auto-
matically ended within 10 milliseconds when an audio signal is present at the inputs.
6
AutoStBy: Setting the waiting time until the power amplifier automatically switches to
standby mode. The standby mode is automatically ended within 2 seconds when audio
signal is present on the inputs.
P1 Go to Home page
P2 Go to DSP page
P3 Go to Tune page
P4 Go to Utility page
P5 Cancel entries, go to Home page