background image

 S-Series 

5 Operation 

12 

 

 

 

 

 

 

 

 

 

 

 

5.5.3

 

DSP Page 

 

Input source 

Type of input: Selection menu (analog, AES3) 

Hardware channel of the selected input: Selection menu (1...4) 

Route In: Input source assigned to the path. Selection menu (a, b, c, d, a+b, c+d) 

Name of the path: Editable via PC software 

Group Values: Lights up green if group-wide parameters (EQ, Gain, Delay) are active. 
Pressing the button resets all group-wide settings on the respective path 

Loudspeaker: Selection menu for loading a loudspeaker (preset) from the internal library. 
When loading multi-way loudspeakers, the amplifier channels on to the right are added to 
this path. 

M: Selection menu for the operating mode of the loaded speaker (e.g. Flat, HP, LP, Cardio, 
etc.) 

Way: Shows the speaker type or speaker way (e.g. Top, Sub, High, Mid, Low, etc.) 

 
With single-channel loudspeakers, the path output is directly at the respective amplifier channels: 
A=1, B=2, C=3, D=4. In the case of multi-way loudspeakers, the first path output is on the respec-
tive direct amplifier channel, the other loudspeaker ways are on the adjacent amplifier channels on 
the right-hand side. 
 

P1  Go to Home page 
P2  Go to DSP page 
P3  Go to Tune page 
P4  Go to Utility page 
P5  Cancel entries, go to Home page 

 

Summary of Contents for 01823

Page 1: ...Hardware Manual S Series Version 1 0 06 10 2022 ...

Page 2: ...Panel 5 4 2 Rear Panel 6 5 Operation 7 5 1 Connections 7 5 2 Start up 7 5 3 Signal Flow Basics 8 5 4 Using the User Interface 9 5 5 Display Pages 10 5 5 1 Overview Page 10 5 5 2 Home Page 11 5 5 3 DSP Page 12 5 5 4 Tune Page 13 5 5 5 EQ Page 14 5 5 6 Utility Page 15 6 Technical Specifications 19 7 Declaration of Conformity 20 ...

Page 3: ...ES3 signals can be fed in via the XLR inputs Optionally audio over Ethernet AoE signals can be processed via an AES67 interface Dante compatible The wide range switching power supplies allow operation on mains voltages from 90 to 265 volts They have an active power factor correction PFC and thus relieve the mains supply considerably Thanks to the latest generation of Class D topology the power amp...

Page 4: ...ssociation regulation BGV A2 Electrical systems and equipment or the equivalent of this regulation valid in your country If necessary observe any deviating regulations when using the de vice abroad The amplifier may only be connected to the loudspeakers by a spe cialist INSTALLATION NOTES Note that the airflow to cool these devices is front to back Make sure that there are no objects on the front ...

Page 5: ... can be addressed via Ethernet Green device in operation To switch the operating mode hold down the button for one second 2 Touch Screen Display information and enter settings See the Operation section of this manual 3 Push Encoder Navigation across the display areas changing and entering settings 4 USB Socket For firmware updates and device control without Ethernet ...

Page 6: ...rts 2x RJ45 compatible Neutrik EtherCon sockets for connecting to a network With switch for direct connection daisy chaining to other amplifiers 5 Mains Connection Neutrik PowerCon socket for connection of a 3 wire power cable according to local regulations Socket can be switched under load and has the function of a mains switch For fractions of a second the amplifiers can draw peak currents far i...

Page 7: ... the mains supply is restored the amplifier restores the last operating state If the power amplifier was previously in standby mode this is restored if the power amplifier was previously in operation it switches on again and uses the last settings made This includes all loaded speaker presets level mute delay EQ settings etc If the amplifier is in the standby state it is switched on by pressing th...

Page 8: ... capital letters A B C and D You can choose from the four individual sources as well as the combinations a b and c d Each input path has a User EQ section This provides six multimode filters a high pass filter input delay input gain polarity reversal and muting The user can save all the settings made here as presets on the device via the PC software for later use The Groups section that follows ho...

Page 9: ...functions navigation and value input In the initial state it is in navi gation mode As the encoder is turned each function and button on the display is cycled through in sequence each highlighted by a blue border If the encoder is pressed keyed it switches to input mode then the respective field is framed in red or activates the function of the button e g mute If an input field is selected the val...

Page 10: ...utton Lights up green when signal is present lights up orange when the limiter is active and red when there is overload Toggles between on and mute M when pressed 6 Snapshot Shows the name of the currently loaded snapshot device state 7 Loaded speaker preset 8 Selected loudspeaker operating mode 9 Loudspeaker type or path 10 Display of the total set output signal levels As soon as the power amplif...

Page 11: ... signal level relative to the full scale of the loaded loud speaker 5 T Meter Shows the temperature of the amplifier channels als a percentage 6 Output Signal Indicator Lights up green when signal is present 7 Mute button Mutes the output channel 8 Information panel about loaded speakers operating modes speaker type way 9 Snapshot Shows the name of the currently loaded snapshot device state P1 Go ...

Page 12: ...he internal library When loading multi way loudspeakers the amplifier channels on to the right are added to this path 8 M Selection menu for the operating mode of the loaded speaker e g Flat HP LP Cardio etc 9 Way Shows the speaker type or speaker way e g Top Sub High Mid Low etc With single channel loudspeakers the path output is directly at the respective amplifier channels A 1 B 2 C 3 D 4 In th...

Page 13: ...d equivalent in meters and feet distance appears below 6 MUTE Path muting button Lights up red when mute is active 7 Pol Button to activate the polarity reversal phase reversal of the path Lights up orange when the polarity is reversed With single channel loudspeakers the path output is directly at the respective amplifier channels A 1 B 2 C 3 D 4 In the case of multi way loudspeakers the direct a...

Page 14: ...s in red Tap ping a selected filter again turns the filter on or off 4 Type Selection menu for assigning a filter type PEQ Shelving Bandpass Notch etc 5 Freq Input box for setting the filter center frequency 6 Gain Input box for filter gain boost cut if applicable 7 Q Input box for setting the filter quality if applicable 8 EQ on bypass Shows the operating status of the filter section Lights up gr...

Page 15: ...s of the display 4 AutoDIM Setting the waiting time until the display is automatically dimmed The amplifier remains in operation operating mode button lights up green As soon as the encoder is operated the display is switched on again 5 AutoSLEEP Setting the waiting time until the power amplifier automatically switches to sleep mode In Sleep mode the amplifier channels are disabled The sleep mode ...

Page 16: ...s all snapshots empties all memory slots on the device 5 5 6 2 Amplifier Tab 1 Gain Allows adjustment of the nominal power amp gain in the range of 26dB to 44dB The default value is 32dB This setting has no effect on the limiter thresholds set in the speaker presets 2 LZ HZ Allows switching between low impedance operation Low Z is set by default and operation on 35V 50V 70V and 100V lines 3 0 dBFS...

Page 17: ...of the device editable in manual mode 2 SubNet Mask Shows the currently set subnet mask of the device Editable in manual mode 3 AUTO IP button Activates the automatic address assignment and then lights up red If there is a DHCP server in the network the address will be assigned by it If no DHCP is available the automatic self assignment of an IP address takes place according to the Zero Configurat...

Page 18: ...Reset Tab 1 Process Reset button resets all parameters and processing of the amplifier to their de fault state All settings made and loaded presets are reset The preset libraries snapshots EQ presets stored on the device are retained ...

Page 19: ...Series 6 Technical Specifications 19 6 Technical Specifications The technical data sheet and further information about possible applications and accessories can be found on the Internet at www seeburg com ...

Page 20: ... 60065 DIN EN 55103 1 1996 classes E1 to E4 DIN EN 55103 2 1996 classes E1 to E4 Issuer of this declaration Winfried Seeburg SEEBURG acoustic line GmbH Place Date Senden 01 06 2022 Authorized signature ____________________________________________ The appendices are part of this declaration This declaration certifies compliance with the guide lines mentioned but does not include any guarantee of pr...

Page 21: ...m info seeburg net User Manual All specifications are current at the time of publishing but are subject to change Subject to errors in the description All SEEBURG acoustic line products are intended for professional use only Dante is a registered trademark of Audinate Pty Ltd SpeakON PowerCON and EtherCON are registered trademarks of Neutrik AG ...

Reviews: