V2.0 7-31-12
21
SEQUENCE NUMBER
Procedure:
1.
Call preset point 95 to enter the main menu.
2.
Use the Up/Down cursor to choose [
PANTILT SETTING
], press
[OPEN]
to confirm the
selection and enter sequence set menu.
3.
Under [
PANTILT SETTING
] choose [
SEQUENCE SETUP
] and press
[OPEN]
to confirm the
selection.
4.
Under [
SEQUENCE SETUP
] choose [
SEQUENCE NUMBER
] to enter the sequence number
setting and the parameter will blink.
5.
Up/down P/T to choose a sequence number.
6.
Press
[OPEN]
to confirm the selection.
7.
Press the
[OPEN]
key to save and exit. Press the
[CLOSE]
key to exit directly without saving.
Note:
The sequence number to be edited must be chosen prior to making any changes to the
sequence.
EDIT SEQUENCE
Procedure:
1.
Call preset point 95 to enter the main menu.
2.
Use the Up/Down cursor to choose
[PANTILT SETTING]
and press
[OPEN]
to confirm the
selection.
3.
Under
[PANTILT SETTING]
choose [
EDIT SEQUENCE
] and press
[OPEN]
to confirm the
selection. The list of sequence steps will be shown on screen and the first point will blink,
indicating it can be changed.
4.
Use the Up/down and L/R PTZ controls to assign a preset for each step of the sequence. If a
preset is not assigned to a step, the sequence will skip that step.
4.
Once all steps are set, press the
[OPEN]
key to save and exit. Press the
[CLOSE]
key to exit
directly without saving.
Note:
Each group of parameters has two numbers, the first represents the preset point number
and the second is the dwell time. The dwell time for every preset point is decided by the default time
when it is not changed. The user can also set the dwell time of every preset point individually. Each
sequence supports a maximum of 32 presets.
PATTERN SETUP
The dome camera can record 1000 different PTZ actions continuously, including pan, tilt and zoom
control, iris and focus settings etc. The dome will retrace those movements when the recorded
pattern is played back. 4 patterns can be stored.
PANTILT SETTING PATTERN SETUP
RECORD NEW PATTERN
Procedure:
1.
Call preset point 95 to enter the main menu.
【PANTILT SETTING】
【PRESETS SETUP】
【SEQUENCE SETUP】
→【PATTERN SETUP】
【AUTOSCAN SETUP】
【HOME ACTION】
→ PATTERN NUMBER : 001
TITLE :PAT1
RECORD NEW PATTERN
RUN CONTINUOUSLY
DELETE CURRENT