V2.0 7-31-12
13
Notes:
20 characters can be set. Characters include: 0-9
、
A-Z
、
:<>-. Other text-entry menus
follow this same procedure.
LANGUAGE SELECT
Procedure:
1.
Call preset 95 to enter the main menu.
2.
Use the up/down PTZ controls to choose
[SYSTEM SETTING]
and press
[OPEN]
to confirm
the selection.
3.
Under
[SYSTEM SETTING]
choose
[LANGUAGE SELECT]
and Press
[OPEN]
to confirm
the selection. The language will be flashing.
4.
Use up/down to choose a language.
5.
Press [OPEN] to save and exit this menu item; Press the
[CLOSE]
key to exit immediately
without saving.
CHANGE PASSWORD
Procedure:
1.
Call preset 95 to enter the main menu.
2.
Use the up/down PTZ controls to choose
[SYSTEM SETTING]
and press
[OPEN]
to confirm
the selection and enter the system setting menu.
3.
Under
[SYSTEM SETTING]
choose
[CHANGE PASSWORD]
and press
[OPEN]
to confirm
the selection.
4.
Use the up/down controls to choose letters and numbers for the name, and L/R to navigate to
the next character of the name.
5.
When the name is complete, press
[OPEN]
to confirm. This will save and exit the title menu.
Press
[CLOSE]
to exit without saving.
6.
If there is already a password in place you will be prompted to enter it first. Input the old
password and press the
[OPEN]
key.
“Input New Password” will be shown on the screen. Input
the new password, then re-enter it once more to c
onfirm. “Password Modification Succeed” will
be shown on the screen.
7.
CAUTION:
For security reasons, there is no way for users to bypass or reset the
password settings. If a password is entered incorrectly or forgotten it will be impossible to
access the
camera’s OSD menu. In order to regain access in the event of a lost or forgotten
password, the camera must be re-initialized by the factory.
Note:
The factory-set
original password is“000000”. If you set the dome password as “000000”,
then no password will be required to access the camera.
FACTORY DEFAULT
1.
Call preset 95 to enter the main menu.
2.
Use the up/down PTZ controls to choose
[SYSTEM SETTING]
and press
[OPEN]
to confirm
the selection and enter the system setting menu.
3.
Under
[SYSTEM SETTING]
choose
[FACTORY DEFAULT]
and press
[OPEN]
to reset the
camera to the factory default settings.
SYSTEM RESTART
1.
Call preset 95 to enter the main menu.
2.
Use the up/down PTZ controls to choose
[SYSTEM SETTING]
and press
[OPEN]
to enter the
system setting menu.
3.
Under
[SYSTEM SETTING]
choose [
SYSTEM RESTART]
and press
[OPEN]
to begin the
reset. This process is the same as power-cycling the camera, so the camera will perform its
startup function check.
SYSTEM INFORMATON
Under
[SYSTEM SETTING]
choose
[SYSTEM INFORMATION]
and press
[OPEN]
to confirm the