28
XR500/XR100 User’s Guide
User Menu
XR500/XR100 User’s Guide
29
User Menu
Using the Panic Zone Test (XR500N/E Only)
1. Access the User Menu.
2. Press COMMAND until SYSTEM TEST? displays.
3. Press any Select key. The keypad displays SYSTEM PANICS.
4. Select PANICS.
5. The Panic Zone Test begins automatically and the keypad
displays TRIPS: END.
During the Panic Zone Test, trip each panic zone (or button)
on the system by pressing and holding the panic for 1 to 2
seconds.
Note:
You do NOT have to hold the panic for 2 seconds in normal
mode. You are only required to hold the panic during the
Panic Zone Test because the zone takes additional time to
report when the system is in test mode.
Each time you trip a panic zone, the display number
increments and the keypad buzzer sounds for two seconds.
The number of panic zones tripped constantly displays until
the test ends or no panic zone activity has occurred for 20
minutes.
6. Select END to stop the Panic Zone Test.
7. PANIC TEST OKAY displays when the Panic Zone Test is
completed and all zones tested OK.
8. When the Panic Zone Test ends and a zone failed (did not
trip) during the test, the keypad displays the zone name and
number and the buzzer sounds for one second. Press the
COMMAND key to display the next failed zone.
Note:
During the Panic Zone Test, any zones that fail are not sent
to the receiver unless pre-programmed at installation to be sent.
User Profiles
Add, delete, or change User Profiles, that define the authority of
each user code in the system. Several characteristics define the
authority of each User Profile within the system. Always make sure
that at least one administrator in your system has a profile with
all
authorities and
all
areas.
Note
: User Profiles does not display in the User Menu when your
system is programmed for All/Perimeter or Home/Sleep/Away
operation.
Profile Number
- Each profile may be assigned a unique number
from 1 to 99.
Note
: When adding User Codes for All/Perimeter or Home/Sleep/
Away systems use the default profiles 1 through 10. Refer to the
User Profiles Chart.
Profile Name
- Each profile may be assigned a 16-character name.
The Profile Number is the default name.
Area Number
- Each profile may be assigned specific areas of
the system for arming and disarming. When profiles 1 to 98 are
created, NO areas are assigned by default. The default for profile
99 is ALL areas assigned. Profile 99 is predefined in the system by
the factory.
Access Area Number
- Each profile may be assigned door access
area assignments. Default for profile 1 to 98 is NO areas assigned.
Default for profile 99 is ALL areas assigned. Profile 99 is predefined
at the factory.
Output Group Assignment
- Each profile may be assigned an
output group number from 1 to 10. Default for profile 1 to 98 is
NO output group assigned. Default for profile 99 is output group
10
. Your system may by programmed to turn on an output group
at certain keypads when door access occurs.