Nnn-0000nn
© Copyright 2012 SecureALL Corporation
Page
14
of
22
All Rights Reserved
Important note: The flex cable and socket are very delicate and must be
handled as discussed here to avoid damage.
The flex cable socket is the brown unit at the bottom of the PCB shown above.
Start by pressing in fully the upper moveable part of the socket. Grab both ends
of the moveable part and gently pull until fully extended. Take the flex cable and,
with the blue side facing up, insert it into the socket. Push it in as far as it will go
without force. Holding it in this position, press both sides of the moveable part of
the socket simultaneously until it locks into place. Gently pull on the flex cable to
ensure it is secure. The flex cable should be square to the socket, i.e. the same
amount of blue should be visible at the socket from one side to the other, It
should not be cocked or crooked relative to the socket.
b.
Motor cable (Figure 8b) -
Figure 8b
The motor cable is two-wire, black/red and is inserted into its socket with the
smooth side up. (Note: Other than the flex cable, the cables are keyed and can
only be inserted with the correct orientation into the appropriate socket on the
PCB.)
c.
Latch position cable (Figure 8c) -
Motor cable