Step 15: Commit the new combination to memory.
9.3
Opening with a Mechanical Combination
For this example, we will assume the combination is set to 53-23-67
Step 1: Pull up on the SpinDial Release to disengage the electronics
Step 2: Now rotate the SpinDial 4 full revolutions to the left (or counter clockwise) stop when
you see 53, the first number in our combination, at the Dialing Index the fourth time.
(The Dialing Index is the small red arrow pointing to the numbers in the center of the
SpinDial Release)
Step 3: Now dial to the right until the second number (23) is aligned with the Dialing Index for
the third time. (So pass the number 23 once, twice and stop on the third time.) Stop precisely
on this number.
Step 4: Now dial to the left until the third number (67) is aligned with the Dialing Index for the
second time. (So pass the number 67 once, and stop on the second time.) Stop precisely
on this number.
Step 5: Now rotate the SpinDial to the right until it comes to a stop (within one revolution) Step
6: When the SpinDial comes to a stop the lock is open.
Step 7: Turn your safe handle.
That’s it.
9.4 To Re-Lock the safe when using the mechanical combination:
Step 1: Close the safe door and turn the safe handle.
Step 2: Now rotate the SpinDial at least 4 full turns to the left to “spin-off” the combination.
Step 3: Lock down the SpinDial Release to re-engage the electronics.
10.0 To Reset the Lock back to Factory Default Codes
Perform the following procedure in order to set the electronic code back to the factory default.