27
4.2 Connections and starting of the support box
Power supply : AC PE/5A/50-60Hz, cable with a DE/FR electrical plug is
supplied.
By first use only, plug in electrical cable on X1 outlet of heating module, switch on main
interruptor to start the support box (afterwards, driving of the support box is acieved by
using the control panel of heating module).
4.3 Driving of ventilators
Ventilator driving is achieved by using the control panel of heating module.
- Press key to switch on the ventilator.
- Press key to switch off the ventilator.
Note : X1 outlet is only working if the control panel is switched on (press key ).
4.4 Driving of cooling cycle
Three-station rotary support box with 3 LEDs timers. Each LED is related to a cooling
station.
On completion of the heating cycle and once cooling accessories are on the toolholder :
- Switch plate with hot holder from the heating position to a cooling position by a 120
°
plate rotation. Red LED will light on.
- LED switches off automatically, indicating the cooling process is finished unless a new
rotation occured in the meantime.
If a new rotation occurs, time passed on previous station is deducted from actual LED
time. While plate is rotating, cooling time follows the toolholder in its rotation.
Note: during rotation, LEDs are flashing as long as position is not set.
Caution, while catching the toolholders from cooling stations, they may be hot.
Always wear protective gloves while handling Shrinkfit holders, tools, accessories and
spare parts.