Choose the adapted finned support that correspond to the Shrinkfit holder taper and
install it in the device.
6.1 Preparation before shrinking cycle
Choose the adapted heat focusing stopper that correspond to the tool shank diameter
and install it into the location diameter in the inductor housing (5 heat focusing stopper
are supplied with each heating module, capacities : Ø 3-6,
Ø 8-14, Ø 16-18, Ø 20-25, Ø 32 mm).
6.2 Shrink-grip
Through pneumatic actuation, move the inductor housing downwards on the holder.
The heat focusing stopper must come in contact with the top of the toolholder.
Note: recommended cylindrical tool shank tolerance is h5 or h6 (maximum h5 for Ø 3 to 5 mm, maximum h6 for Ø 6 to 32
mm).
6. SHRINKING
Select heating cycle corresponding to the Shrinkfit holder (see
§
2.8.1),
The heating cycle runs automatically according to the tool diameter and Shrinkfit
holder taper type.
Mode PRG
Select the tool diameter by using the arrows on the control panel. Selection can be
followed up on display.