18
•
Inductor housing setting in relation with the support modules
Install a heat focusing stopper onto the inductor housing.
Using a toolholder, set on the finned support, under the inductor, check the
alignment of the inductor in comparison to the finned support.
Favourable case: the focusing stopper is
properly aligned.
The inductor is ready to be used.
Unfavourable case: the focusing stopper is out
of alignment, proceed to the following set of
instruction (
§
B).
A. Procedure to check the alignment of the inductor
- Unscrew the two lower screws of the inductor.
- Unscrew the two upper screws of the inductor.
If the heat focusing stopper is out of alignment (cf. A above):
You have now access to the upper screws of the inductor.
- unscrew the two screws of the comparator,
- remove the comparator.
B. Centring of the inductor