SECO-LARM U.S.A., Inc.

 

Note: The mounting tabs are only used for 

aluminum and metal door frames. This is 

commonly done when retrofitting door frames. 

To mount the strike where the hollow door frame 

material is unsuitable for mounting, do the following: 

1.

 

Punch or drill holes according to the template 

for installation of the mounting tabs, and the 

anchor nuts that reinforce them. 

2.

 

When installing, do not over-tighten the screws 

as small adjustments may be required to 

secure a snug fit for the door strike. 

Mounting the Strike Using Mounting Tabs: 

 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 

 

 
 

 

Mounting Tabs 

Using the stick-on template as a guide: 

1.

 

Drill holes for mounting the strike, and cut a 

hole for the face-plate size being used. It is 

recommended to cut the hole slightly 

smaller than necessary.  

2.

 

Use a file to finish the shaping of the frame. 

This will improve the fit and finish of the 

installation. 

Preparing the Door Frame: 

Note: Trim plate is optional and may not be 

required in all installations. Only use the trim 

plate to cover any gaps in the door frame.  

Mounting the Trim Plate: 

1.

 

If the hole cut for the faceplate is too large 

or is jagged, the trim plate can be mounted 

over the hole to improve the appearance of 

the installation. 

2.

 

Screw the trim plate into the mounting holes 

at the top and bottom of the door strike 

using the included trim plate screws before 
installing the strike to the door frame. 

Machine 

Screws 

Summary of Contents for SD-996C-U1VQ

Page 1: ...12VDC 150mA 24VDC SD 996C NUVQ Vertical adjustable deadbolt opening sliding shim keeper and deadlatch ramp accommodates a wide range of lock types Accommodates deadbolts up to 1 Field selectable for f...

Page 2: ...s pre cut for a strike skip to step 6 2 Measure and mark the door latch line and the center line of the door See Measuring the Latch Line Center Lines page 3 3 Apply the included stick on template to...

Page 3: ...distance X from the side of the door frame and distance Y from the top of the door frame Use a pencil to mark the exact spot where the two lines intersect 2 Carefully peel off the short thin tab in t...

Page 4: ...g the stick on template as a guide 1 Drill holes for mounting the strike and cut a hole for the face plate size being used It is recommended to cut the hole slightly smaller than necessary 2 Use a fil...

Page 5: ...11D2Q faceplates with the mounting tabs shown in Mounting the Strike Using Mounting Tabs page 4 SD 996SS 11L1Q Note If it is necessary to cut a hole in the frame mounting tabs may be required to stre...

Page 6: ...on the head of the connector 12 24 VAC VDC Wiring Diagram for SD 996C NUVQ FAIL SECURE FAIL SAFE SECO LARM Diagrams are for illustrative purposes only Polarity of wires is not important IMPORTANT War...

Page 7: ...d adjust the deadbolt keeper up and down to align with the marked lines Adjusting Deadbolt Keeper 1 Move the door close to the strike and mark the deadlatch limit lines on the strike keeper when they...

Page 8: ...ecifications without notice SECO LARM is not responsible for misprints Trademarks are the property of SECO LARM U S A Inc or their respective owners Copyright 2016 SECO LARM U S A Inc All rights reser...

Reviews: