Troubleshooting: 

Also Available from 

SECO-LARM

®

Electric strike does not activate

 

 

Dismount the strike and check that the electrical connector is 

connected properly.  

 

Ensure the electrical connector is connected to a 12 or 24VDC 

source. 

 

Use a multimeter to test that the strike is receiving the proper 

voltage and amperage. If it is not, it may be necessary to use 

heavier gauge wires, or increase the output of the power supply. 

 

Make sure the activation device (keypad or push-button switch) is 

working properly. 

Door does not open when the 

electric strike is activated

 

 

Check that the door latch is operating properly, and replace if 

necessary. 

 

The position of the electric strike may need to be adjusted by 

moving it or adding washers or shims. 

Strike makes a buzzing sound 

 

Use DC power supply instead of AC power  

 

NOTICE:  The SECO-LARM policy is one of continual development and improvement. For that reason, SECO-LARM 

reserves the right to change specifications without notice. SECO-LARM is not responsible for misprints. Trademarks are the 

property of SECO-LARM U.S.A., Inc. or their respective owners. 

Copyright © 2016 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or 

in part, without the written permission of SECO-LARM. 

 

LIMITED WARRANTY:

 

This SECO-LARM product is warranted against defects in material and workmanship while used in 

normal service for three (3) years from the date of sale to the original customer. SECO-LARM’s obligation is limited to the 

repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is 

void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration, 

improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is 

not operating properly as a result of causes other than defects in material and workmanship.  The sole obligation of 

SECO

-

LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO-LARM’s 

option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property 

damage of any kind to the purchaser or anyone else. 

 

SECO-LARM

®

 

U.S.A., Inc

.

 

16842 Millikan Avenue, Irvine, CA 92606  Website: www.seco-larm.com 

 

PITGW1

 

Phone: (949) 261-2999 |  (800) 662-0800  Email: [email protected] 

MI_SD-996C-xxVQ_160523.docx 

 

Summary of Contents for SD-996C-U1VQ

Page 1: ...12VDC 150mA 24VDC SD 996C NUVQ Vertical adjustable deadbolt opening sliding shim keeper and deadlatch ramp accommodates a wide range of lock types Accommodates deadbolts up to 1 Field selectable for f...

Page 2: ...s pre cut for a strike skip to step 6 2 Measure and mark the door latch line and the center line of the door See Measuring the Latch Line Center Lines page 3 3 Apply the included stick on template to...

Page 3: ...distance X from the side of the door frame and distance Y from the top of the door frame Use a pencil to mark the exact spot where the two lines intersect 2 Carefully peel off the short thin tab in t...

Page 4: ...g the stick on template as a guide 1 Drill holes for mounting the strike and cut a hole for the face plate size being used It is recommended to cut the hole slightly smaller than necessary 2 Use a fil...

Page 5: ...11D2Q faceplates with the mounting tabs shown in Mounting the Strike Using Mounting Tabs page 4 SD 996SS 11L1Q Note If it is necessary to cut a hole in the frame mounting tabs may be required to stre...

Page 6: ...on the head of the connector 12 24 VAC VDC Wiring Diagram for SD 996C NUVQ FAIL SECURE FAIL SAFE SECO LARM Diagrams are for illustrative purposes only Polarity of wires is not important IMPORTANT War...

Page 7: ...d adjust the deadbolt keeper up and down to align with the marked lines Adjusting Deadbolt Keeper 1 Move the door close to the strike and mark the deadlatch limit lines on the strike keeper when they...

Page 8: ...ecifications without notice SECO LARM is not responsible for misprints Trademarks are the property of SECO LARM U S A Inc or their respective owners Copyright 2016 SECO LARM U S A Inc All rights reser...

Reviews: