G.5
Checking and adjusting the J clearance
The J clearance is the operating clearance for the indirect and manual releases.
J = 0.4
+0.3/-0
mm for BIM5 and BIM6 indirect releases
J = 1.0
±0.25
mm for the M3 manual release.
Note!
This measurement is taken with the circuit-breaker closed.
G.5.1
Measurement
Measure the J clearance between the fork (3) and the plate (2) (using the recommended
Sécheron’s “J-IND” or “J-M3” gauges). If needed adjust the J clearance.
02779
G.5.2
Adjustment
a) Loosen the screw(s) (7).
b) Rotate (8) the shaft (2) until the proper J clearance is obtained.
Note!
The stroke (K) must be of 17± 2 mm.
c) Tighten the screw(s) (7).
03548
J
3
2
5
Important!
After the adjustment, at least two open/closing operations must be performed prior
to rechecking the clearance to check that nothing interferes with the movement of
the fork (3) as well as with its hooking on the catch (5).
K