Controller
The central controller allows for setting the desired temperature (°C and °F), as well as the press
duration in seconds.
Operation
● Use the the supplied power cord to connect the heat press to a 230V socket.
● The red toggle switch turns the press ON.
● Press the
SET
Button in the
Temperature
field to set the desired temperature using the
arrow keys. Confirm the value by pressing the
SET
button again.
● Press the
SET
Button in the
Time
field to set the desired pressing time using the arrow
keys. Confirm the value by pressing the
SET
button again.
● The press will now heat up to the set temperature.
● Now you're ready to perform your first transfers. The clock starts counting as soon as the
press is closed with the press lever.
● 3 seconds before the set time runs out, a warning signal is sounded.
● After the time has elapsed, the press must be opened manually.
● You can adjust the contact pressure by turning the large hand screw at the top of the press
to increase or decrease the distance the lever travels. Turning the knob clockwise
decreases the contact pressure, while turning it counterclockwise increases it.
● No settings can be changed at the controller while a press operation is in progress.
Note: Please keep in mind that it takes some time for the press to cool off after it is
switched off.
Secabo GmbH Hochstatt 6-8 85283 Wolnzach Alemania [email protected] www.secabo.com