Sebury F007-EM User Manual Download Page 5

 

Remark: 

F007-EM  can  connect  both  types  of  the  locks  directly,  no  matter  it’s  Fail  secure  (unlock  when 

power on) or Fail safe (unlock when power off). Please check Manager Operation – Item 5 for the 

lock setting.   

4, Manager Operation   

There are 3 ways to add and delete users:  1, by Manager card;  2, by remote control;  3, by 

Manager fingerprint 

  1, By Manager Card (the most convenient way) 

      1.1 Add Fingerprint user 

 

Manager  add  card      Enter  1

st

  User  Fingerprint  Twice      2

nd

  User  Fingerprint 

Twice  …  Manager add card 

Note: When add fingerprint, please input each fingerprint twice, during which the LED shines 

red  then  turn  green,  means  the  Fingerprint  is  enrolled  successfully.  When  delete  fingerprint,  just 

input it once 

1.2 Add Card user 

Manager add card   1

st

 User card   2

nd

 User card  …  Manager add card 

 

Remark

Fingerprint user ID is 3-162, Card user ID is 163

2162

when add fingerprint or 

Card  by  Manager  card,  it  is  produced  automatically  from  3-160  or  163  to  2162.  (ID  1,  2  are 

belong to Manager fingerprint)   

  1.3 Delete users 

Manager delete card   card  OR  Fingerprint once  …  Manager delete card 

   

To delete more than 1 card or fingerprint, just input card or fingerprint continuously.     

Note: When delete fingerprint, please input it once.   

 

2, By Remote Control 

Enter into programming mode: 

Summary of Contents for F007-EM

Page 1: ...EM EM EM Fingerprint Fingerprint Fingerprint Fingerprint RFID RFID RFID RFID Access Controller Access Controller Access Controller Access Controller User Manual User Manual User Manual User Manual Se...

Page 2: ...hange the master code 0 new code repeat the new code code 6 8 digit Add fingerprint user 1 Fingerprint repeat Fingerprint can add Fingerprints continuously Add card user 1 Card can add Cards continuou...

Page 3: ...one it can connect to other controller as the salve reader 2 pcs F007 EM can interconnect 2 pcs F007 EM can be interlocked Remote infrared programmer Manager card for programming Anti magnetic lock ou...

Page 4: ...circuit 3 3 Method of Reset to Factory default setting and re register Manager cards Power off press the RESET key SW14 on the PCB hold it and power on release it until hear two short beeps the LED sh...

Page 5: ...se input each fingerprint twice during which the LED shines red then turn green means the Fingerprint is enrolled successfully When delete fingerprint just input it once 1 2 Add Card user Manager add...

Page 6: ...pointment To add fingerprint users 1 ID number User Fingerprint Fingerprint User ID number can be any digit between 3 162 but one ID number to one user To add fingerprint users continuously 1 3 1st Us...

Page 7: ...s delete fingerprint To delete Card users Manager s delete fingerprint Card 1 Card 2 Manager s delete fingerprint 4 Delete all the users manager password 20000 Note This will delete all fingerprints...

Page 8: ...or Manager Password Any of the method above can remove the alarm 9 Two devices interlock setting manager password 8 0 to disable this function factory default setting 8 1 to enable this function 10 S...

Page 9: ...necting to Controller F007 EM supports wiegand output it can be connected to the controller which support wiegand 26 input as its slave reader the connection diagram is as figure 1 Supply Voltage 12VD...

Page 10: ...0 255 For example device ID was set 255 fingerprint ID is 3 then its ID to the controller is 255 00003 2 F007 EM works as Controller connecting slave reader F007 EM supports wiegand input any card re...

Page 11: ...e If the master password was set different the user enrolled in the outdoor unit can t access from outside 4 Two device interconnected interlocked two doors The connection is showed as Figure 4 for th...

Page 12: ......

Reviews: