Sebury F007-EM User Manual Download Page 11

 

  3. Two F007-EM interconnected - single door 

Wiegand  output,  Wiegand  input:  The  connection  is  showed  as  Figure  3.  One  F007-EM 

installed inside the door, the other outside the door, two devices interconnect. Either device acts 

as the controller and reader at the same time. It has below feature:   

2.1

 

Users can be enrolled on either of the device. The information of the two devices can be 

communicated. In this situation the user capacity for one door can be up to 4320. Each 

user can use fingerprint or password for access. 

2.2

 

The  setting  of  the  two  F007-EM  must  be  the  same.  If  the  master  password  was  set 

different, the user enrolled in the outdoor unit can’t access from outside. 

 

 

  

 

 

  

 

4. Two device interconnected & interlocked – two doors 

The connection is showed as Figure 4, for the two doors, each door install one controller 

and one lock related. The interlocked function will go when either door is opened, the other 

door is locked forced, only close this door, the other door can be opened.   

The  interlocked  function  is  mainly  using  in  bank,  prison,  and  other  places  where  require 

higher security. Two doors are installed for one access. 

The  user  enters  fingerprint  or  card  on  controller  1,  the  door  1  will  open,  the  user  enters, 

and close door 1, only after that, the user can open the second door by entering fingerprint 

or card on second controller.   

 

Summary of Contents for F007-EM

Page 1: ...EM EM EM Fingerprint Fingerprint Fingerprint Fingerprint RFID RFID RFID RFID Access Controller Access Controller Access Controller Access Controller User Manual User Manual User Manual User Manual Se...

Page 2: ...hange the master code 0 new code repeat the new code code 6 8 digit Add fingerprint user 1 Fingerprint repeat Fingerprint can add Fingerprints continuously Add card user 1 Card can add Cards continuou...

Page 3: ...one it can connect to other controller as the salve reader 2 pcs F007 EM can interconnect 2 pcs F007 EM can be interlocked Remote infrared programmer Manager card for programming Anti magnetic lock ou...

Page 4: ...circuit 3 3 Method of Reset to Factory default setting and re register Manager cards Power off press the RESET key SW14 on the PCB hold it and power on release it until hear two short beeps the LED sh...

Page 5: ...se input each fingerprint twice during which the LED shines red then turn green means the Fingerprint is enrolled successfully When delete fingerprint just input it once 1 2 Add Card user Manager add...

Page 6: ...pointment To add fingerprint users 1 ID number User Fingerprint Fingerprint User ID number can be any digit between 3 162 but one ID number to one user To add fingerprint users continuously 1 3 1st Us...

Page 7: ...s delete fingerprint To delete Card users Manager s delete fingerprint Card 1 Card 2 Manager s delete fingerprint 4 Delete all the users manager password 20000 Note This will delete all fingerprints...

Page 8: ...or Manager Password Any of the method above can remove the alarm 9 Two devices interlock setting manager password 8 0 to disable this function factory default setting 8 1 to enable this function 10 S...

Page 9: ...necting to Controller F007 EM supports wiegand output it can be connected to the controller which support wiegand 26 input as its slave reader the connection diagram is as figure 1 Supply Voltage 12VD...

Page 10: ...0 255 For example device ID was set 255 fingerprint ID is 3 then its ID to the controller is 255 00003 2 F007 EM works as Controller connecting slave reader F007 EM supports wiegand input any card re...

Page 11: ...e If the master password was set different the user enrolled in the outdoor unit can t access from outside 4 Two device interconnected interlocked two doors The connection is showed as Figure 4 for th...

Page 12: ......

Reviews: