8.  Overview of all functions   

 

Commissioning 

With the activation of the device 

(see chapter 6.1

) a beep 

sounds and all three LEDs flashes up briefly at the same time.  

Deactivation of the CO 
alarm detector 

The CO alarm detector can be deactivated. This function is 
required when e.g. the battery is too low and the device must be 
replaced. In chapter 

„Information about the built-in-battery“ is 

described how the device is deactivated. 

Note:

 The deactivation 

can not be undone anymore! 

Error warning 

If the device beeps once every 30 seconds and the yellow LED 
(FAULT) flashes, the alarm will not work. No CO-gas is detected 
and no warning signal is sent. The CO alarm detector is 
defective or the battery is empty. Replace the CO alarm 
detector! 

Low battery voltage (battery 
warning signal) 

If the device beeps twice every 30 seconds and the yellow LED 
(FAULT) flashes, the battery is empty. Replace the CO alarm 
detector as soon as possible! 

Muting the battery warning 
signal 

If the device sends the battery warning signal, press the button 
TEST / SILENCE. The warning tone is muted for approx. 9 hours 
while the yellow LED (FAULT) continues to flash every 30 
seconds. 

Warning of the end of life 

If the device beeps three times every 30 seconds and the yellow 
LED (FAULT) flashes, the end of life of the device is reached  

CO-alarm warning 

At a dangerously high CO-concentration, the red LED (ALARM) 
flashes four times in succession with four short loud beeps every 
5 seconds. The alarm will sound until the CO-concentration has 
returned to normal in the room or is not dangerous anymore. In 
this case please follow the instructions which is given in chapter 
„What to do if alarms were trigged“! 

Mute the CO-Alarm 

Attention:

 The muting may be carried out only under the 

condition that is certain that the air does not have a too high CO-
concentration. Please check your device, such as gas heaters, 
fireplaces etc., by a specialist before muting the device!  

To mute the device press the TEST/SILENCE button. The signal 
tone is switched off for approx. 5 minutes while the red LED 
(ALARM) continues to flash shortly for times briefly. The signal 
tone is reactivated within 6 minutes after pressing 
TEST/SILENCE button. The alarm is triggered with an existing 
CO-concentration of more than 45ppm. 

Volume 

When the CO alarm sounds, the beep starts with a lower volume 
of <85dB for about 10 seconds before reaching the full volume 
of> 85dB. This is to avoid that persons present are startled by 

Summary of Contents for GS810

Page 1: ...r should be installed 4 4 Product Overview 6 5 Installation 6 6 Startup 7 6 1 Activation of the CO alarm detector 7 6 2 Checking the function of the CO alarm detector 8 6 3 Recurring self test of the...

Page 2: ...alarm sounds This CO alarm detector may only be used in private rooms The CO alarm detector must be activated before use see chapter 6 1 After a maximum of 10 years as well as with signaling the batt...

Page 3: ...e following symptoms appear by a carbon monoxide poisoning The symptoms of carbon monoxide poisoning are similar to influenza but without fever Other symptoms are dizziness tiredness weakness headache...

Page 4: ...ple using a screwdriver pliers hammer etc Do not drop the device because this can damage it The conversion of this product is not allowed Any other use than the description may result in damage to the...

Page 5: ...entilators Do not install near ventilation systems chimneys or exhaust pipes as well as doors and windows as this may have a lower carbon monoxide concentration Keep the CO alarm detector away from st...

Page 6: ...mute 4 FAULT Error display yellow LED 5 POWER Control light green LED 5 Installation Before starting up this product please check for external damage In case of visible external damage we immediately...

Page 7: ...e screw until the screw head protrudes about ca 55mm from the wall 3 The mounting hole for the screw is located on the rear of the housing Insert the screw head into the mounting hole and press the CO...

Page 8: ...urring self test of the CO alarm detector When operating properly the green LED POWER flashes every 30 seconds Note If the CO alarm detector is not working properly contact the manufacturer 7 Explanat...

Page 9: ...flash every 30 seconds Warning of the end of life If the device beeps three times every 30 seconds and the yellow LED FAULT flashes the end of life of the device is reached CO alarm warning At a dange...

Page 10: ...have arrived The alarm must not be deactivated during this time 6 Do not restart the switched off combustion device until it has been checked by an expert 7 Check each combustion device If no special...

Page 11: ...chapter Installation The battery will last approximately 10 years during normal operation If the unit beeps twice every 30 seconds and the yellow LED FAULT flashes the battery is empty and the CO alar...

Page 12: ...free from contamination at all times in order to ensure proper functioning Note Never open the housing to clean the unit from the inside This can impair the functionality and the warranty guarantee wi...

Page 13: ...e harmful Substances which are contained in the batteries may cause danger to health and the environment in case of improper disposing 14 General Disposal This product may not be disposed of with hous...

Reviews: