background image

 

LZR -U901

®

USER’S GUIDE

BLUE LED

ORANGE LED

POWER ON

ERROR

Adjustable bracket

Cable conduit

LED-signal

Laser sweep
reception

Laser sweep
emission

Tilt angle

adjustments

Main
connector

Front screens

SAFETY INSTRUCTIONS

DESCRIPTION

ENGLISH

MEASUREMENT DEVICE BASED ON LASER TECHNOLOGY*

*Other use of the device is outside the permitted purpose and can not be guaranteed by the manufacturer.

Caution! Use of controls, adjustments or performance of 
procedures other than those specified herein may result in 
hazardous radiation exposure.

Do not stare into the 
laser emitter.

Do not open the sensor. 
Warranty is void if 
opened.

The sensor should only 
be installed and 
adjusted by authorized 
and trained staff.

The device contains IR and visible red laser diodes.

IR laser (CLASS 1): 

wavelength 905nm
max. output pulse power 75W

Summary of Contents for LZR -U901

Page 1: ...ce is outside the permitted purpose and can not be guaranteed by the manufacturer Caution Use of controls adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure Do not stare into the laser emitter Do not open the sensor Warranty is void if opened The sensor should only be installed and adjusted by authorized and trained staff The devic...

Page 2: ...es in the detection field Wipe the front screens regularly with a clean and damp cloth Do not use aggressive detergents or abrasive cleaning agents to clean the front screens Avoid condensation INSTALLATION TIPS Make a hole for the cable if possible Drill 4 holes as indicated on the mounting template Use the adhesive mounting template to position the sensor correctly The grey area indicates the de...

Page 3: ...r Check cable and connexion Orange LED is ON No blue LED There is no power The sensor exceeds its temperature limits The power supply voltage is exceeding the acceptable limits Internal error LED SYMPTOMS POSSIBLE CAUSES CORRECTIVE ACTION Adjust the tilt angle of the sensor Adjust the lateral position Lock the position of the bracket to avoid malfunctioning To unlock use a screwdriver WIRING TROUB...

Page 4: ...LED power on status 1 orange LED error status 125 mm D x 93 mm W x 70 mm H mounting bracket 14 mm PC ASA black 45 0 45 5 to 5 lockable 3 to 3 IP65 avoid direct exposure to high pressure cleaning 30 C to 60 C if powered 10 C to 60 C unpowered 0 95 non condensing 2 G max 30 homogenous designed for a lifetime of min 8 years 2006 95 EC LVD 2002 95 EC RoHS EN 61000 6 2 EMC Industrial level 10 0 3516 96...