TECHNICAL SPECIFICATIONS

Technology:

Measurement range:

Nbr of planes: 

Nbr of points/plane: 

Angular resolution: 

Angular coverage: 

Rotating speed: 

Remission factor:

Emission characteristics:

Supply voltage:

Power consumption:

Peak current at power-on:

Serial communication*:

   Type 

   Interface

   Communication mode

   Transmission speed

   Topology

   Symbol coding

   File type

LED-signal:

Dimensions:

Material:

Colour:

Mounting angles on bracket:

Rotation angles on bracket:

Tilt angles on bracket:

Protection degree:

Temperature range:

Humidity:

Vibrations:

Pollution on front screens:

Expected lifetime:

Norm conformity:

IR laser (CLASS 1)

laser scanner, time-of-flight measurement

10 m x 

 m @ 2 % remission factor

4

274

> 2 %

wavelength 905 nm; max. output pulse power 75 W

10 V - 35 V DC @ sensor terminal 

< 5 W

1.8 A (max. 80 ms @ 35 V)

1 blue LED: power-on status; 1 orange LED: error status

125 mm (D) x 93 mm (W) x 70 mm (H) (mounting b 14 mm)

PC/ASA

black

-45 °, 0 °, 45 °

-5 ° to +5 ° (lockable)

-3 ° to +3 °

IP65 (avoid direct exposure to high pressure cleaning)

-30 °C to +60 °C if powered

-10 °C to +60 °C unpowered

0-95 % non-condensing

< 2 G 

max. 30 %; homogenous

designed for a lifetime of min. 8 years

2006/95/EC: LVD

2002/95/EC: RoHS; 

EN 61000-6-2: EMC - Industrial level; 

10

0.3516°

96.3281 °

900 turns/min

asynchronous

RS 485

half-duplex

460800 bit/sec

point to point

1 start bit, 1stop bit, no parity bit

8 bits

; 2004/108/EC: EMC; 

EN 60529; EN IEC 60825; EN 60950-1; 

EN 61000-6-3: EMC - Commercial Level

Specifications are subject to change without prior notice.

©BEA

42.7279 -V2 / 09.10

 

 

/ Original instructions /

Jean-Pierre Valkenberg, R&D Manager (

)

Authorized representative

Liege, June 2010

The complete declaration of conformity is available on our website: www.bea.be

BEA hereby declares that the LZR -U901 is in conformity with the basic requirements and the other 
relevant provisions of the standard 2004/108/EC.

®

* see application note LZR-U90X Protocol (request by mail, phone or download on the internet)

®

Summary of Contents for LZR -U901

Page 1: ...ce is outside the permitted purpose and can not be guaranteed by the manufacturer Caution Use of controls adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure Do not stare into the laser emitter Do not open the sensor Warranty is void if opened The sensor should only be installed and adjusted by authorized and trained staff The devic...

Page 2: ...es in the detection field Wipe the front screens regularly with a clean and damp cloth Do not use aggressive detergents or abrasive cleaning agents to clean the front screens Avoid condensation INSTALLATION TIPS Make a hole for the cable if possible Drill 4 holes as indicated on the mounting template Use the adhesive mounting template to position the sensor correctly The grey area indicates the de...

Page 3: ...r Check cable and connexion Orange LED is ON No blue LED There is no power The sensor exceeds its temperature limits The power supply voltage is exceeding the acceptable limits Internal error LED SYMPTOMS POSSIBLE CAUSES CORRECTIVE ACTION Adjust the tilt angle of the sensor Adjust the lateral position Lock the position of the bracket to avoid malfunctioning To unlock use a screwdriver WIRING TROUB...

Page 4: ...LED power on status 1 orange LED error status 125 mm D x 93 mm W x 70 mm H mounting bracket 14 mm PC ASA black 45 0 45 5 to 5 lockable 3 to 3 IP65 avoid direct exposure to high pressure cleaning 30 C to 60 C if powered 10 C to 60 C unpowered 0 95 non condensing 2 G max 30 homogenous designed for a lifetime of min 8 years 2006 95 EC LVD 2002 95 EC RoHS EN 61000 6 2 EMC Industrial level 10 0 3516 96...