background image

 

6.2 Checking the function of the CO alarm detector 

 

To test the CO alarm detector please keep the device at least one arm's length away from your 
body before performing the function check! Your hearing may be damaged by the loud alarm 
sound! Then briefly press the TEST/SILENCE button. When the alarm sounds in succession 4x 
and the LED lights up red while the device is working properly. It checks whether the electronics, 
the alarm sensor of the CO alarm detector and the batterie are working properly. The alarm will 
automatically turn off after the TEST/SILENCE button is released. 

Note:

 Test the device weekly! If the test alarm is not performed as described, replace the CO 

alarm detector immediately! 

 

6.3 Recurring self test of the CO alarm detector 

 

When operating properly, the green LED (POWER) flashes every 30 seconds. 

Note:

 If the CO alarm detector is not working properly, contact the manufacturer! 

 

7.  Explanation of the LED modes 

 

 

 
 
 
 
 

Green LED (POWER) flashes every 3 second 
for about ca. 30 seconds:

 

Warm-up after activation 

– everything ok 

Green LED (POWER) flashes every 30 
seconds:

 

Device is working properly 

Yellow LED (FAULT) flashes and beeps 

1x

 

every 30 seconds:

 

The device is defective or the battery is low. 
Replace the device! 

Yellow LED (FAULT) flashes and beeps 

2x

 

every 30 seconds:

 

Battery is empty. The device must be replace. 

Yellow LED (FAULT) flashes and beeps 

3x

 

every 30 seconds:

 

The device must be replace. Sensor does not 
work properly! Device is too old! 

RED LED (ALARM) flashes and beeps 

4x

 

shortly every 5 seconds: 

Hazardous CO concentration recognized. CO-
Alarm! In this case please follow the steps 
described in 

Chapter 9

Summary of Contents for GS810

Page 1: ...r should be installed 4 4 Product Overview 6 5 Installation 6 6 Startup 7 6 1 Activation of the CO alarm detector 7 6 2 Checking the function of the CO alarm detector 8 6 3 Recurring self test of the...

Page 2: ...alarm sounds This CO alarm detector may only be used in private rooms The CO alarm detector must be activated before use see chapter 6 1 After a maximum of 10 years as well as with signaling the batt...

Page 3: ...e following symptoms appear by a carbon monoxide poisoning The symptoms of carbon monoxide poisoning are similar to influenza but without fever Other symptoms are dizziness tiredness weakness headache...

Page 4: ...ple using a screwdriver pliers hammer etc Do not drop the device because this can damage it The conversion of this product is not allowed Any other use than the description may result in damage to the...

Page 5: ...entilators Do not install near ventilation systems chimneys or exhaust pipes as well as doors and windows as this may have a lower carbon monoxide concentration Keep the CO alarm detector away from st...

Page 6: ...mute 4 FAULT Error display yellow LED 5 POWER Control light green LED 5 Installation Before starting up this product please check for external damage In case of visible external damage we immediately...

Page 7: ...e screw until the screw head protrudes about ca 55mm from the wall 3 The mounting hole for the screw is located on the rear of the housing Insert the screw head into the mounting hole and press the CO...

Page 8: ...urring self test of the CO alarm detector When operating properly the green LED POWER flashes every 30 seconds Note If the CO alarm detector is not working properly contact the manufacturer 7 Explanat...

Page 9: ...flash every 30 seconds Warning of the end of life If the device beeps three times every 30 seconds and the yellow LED FAULT flashes the end of life of the device is reached CO alarm warning At a dange...

Page 10: ...have arrived The alarm must not be deactivated during this time 6 Do not restart the switched off combustion device until it has been checked by an expert 7 Check each combustion device If no special...

Page 11: ...chapter Installation The battery will last approximately 10 years during normal operation If the unit beeps twice every 30 seconds and the yellow LED FAULT flashes the battery is empty and the CO alar...

Page 12: ...free from contamination at all times in order to ensure proper functioning Note Never open the housing to clean the unit from the inside This can impair the functionality and the warranty guarantee wi...

Page 13: ...e harmful Substances which are contained in the batteries may cause danger to health and the environment in case of improper disposing 14 General Disposal This product may not be disposed of with hous...