background image

TROUBLE-SHOOTING GUIDE

PROBLEM

Does not turn on

or machine shuts off

intermittently

Bag full or clog light on

or flashing &

machine shuts off

(red light A see page 9,

figure 7, also, see page 4)

Brush light on or flashing

(red light B see page 9,

figure 7, also, see page 4)

Brush light flashing &

machine shuts off

(red light B, page 9, also,

see page 4)

Does not pick up

Front bag door won’t

fully close

Hose doesn’t retract

after cleaning wand is

inserted

REASON

1. Handle not fully inserted into the bag

housing, causing a faulty connection.

2. Not plugged into good outlet.

3. Cable worn.

4. Bag housing (6) not seated fully

into proper “locked” position

on top of power head.

1. Bag full.

2. Clog in airflow pathway, attach-

ment hose, cleaning wand, swivel

neck or entrance to filter bag.

3. Microfilter dirty.

1. Brush worn.

2. Incorrect brush setting

1. Brush jammed or clogged.

2. Brush is too low for the surface

being vacuumed.

1. Cleaning wand not correctly

inserted.

2. Front cover not closed.

1. Cover release flap not fully closed.

2. Bag not inserted properly.

3. Microfilter not properly inserted.

1. Cleaning wand not properly

inserted.

SOLUTION

1. Release handle catch, push handle

down, close handle catch.

2. Use another outlet.

3. Replace cable.

4. Housing release button (8) should

be snapped outward to its locked

position.

1. Replace bag. See page 10.

2. See Clog Removal on page 11.

3. Replace microfilter. See page 10.

1. Replace brush. See page 10.

2. Adjust the brush by turning the pile

adjustment knob up or down.

1. Clear jam. See page 11.

2. Raise the brush by turning the pile

adjustment knob up.

1. Reinsert cleaning wand, making

sure lower end of tube is in the

lower hole and handle is properly

seated over the projection tab (23).

2. See below.

1. Reinsert bag. Lock the cover

release flap down firmly.

2. Reinsert bag with cover release

flap (5) up, until firmly latched in

bag holder (see pg. 10, figure 9).

3. Lift safety lever and insert filter with

vertical plastic ridge on filter facing

you (see pg. 10, figure 10).

1. Reinsert making sure top of handle

is pointing back and tube is fully

seated on the protruding tab (23)

on top of the bag housing.

Always unplug vacuum from outlet before dismantling any part of the machine!

!

12

Summary of Contents for 90406AM

Page 1: ...OWNER S MANUAL For Household Use Only...

Page 2: ...ccessories Bags Filters 6 Identification of Parts 7 Standard Attachments 7 Assembly 7 Operating Instructions 8 Starting the Machine 8 Operating Positions 8 Using the Cleaning Wand Hose Attachments 9 T...

Page 3: ...near flammable vapors or materials Do not operate this vacuum near flammable fluids dust or vapors 21 Maintenance and repairs must be done by qualified personnel 22 Use only original SEBO replacement...

Page 4: ...H light flashes continuously while the head is in position 1 after a 10 second delay it is signalling the user that the brush roller is too worn and therefore should be replaced The light will remain...

Page 5: ...rly maintained SEBO vacuums save ordinary residential users hundreds of dollars by providing excellent performance for ten to fifteen years or more and their deep cleaning power brush technology exten...

Page 6: ...multiple item attachment kits Another popular attachment is the hand held turbo brush for removing pet hair from upholstery SEBO Ultra filter bags can be purchased in boxes of eight and filters are s...

Page 7: ...ition Slide the dusting brush clamp 25 onto the handle tube 3 and tighten the screw The handle of the dust ing brush 26 will now snap into the clamp To insert the handle tube 3 into the housing lift t...

Page 8: ...be pressed a second time The intermediate stop position can be closed off by the orange colored slider 28 on the back of the swivel neck 20 so that the handle will go from vertical to horizontal in on...

Page 9: ...f the bag hous ing and the power head is locked in a perpendicular position to the floor Ensure that no children or pets can come into contact with the spinning brush roller To vacuum walls under beds...

Page 10: ...r Microfilter Figure 10 The pre motor microfilter 31 needs to be changed when it becomes extremely dirty or clogged with dust or after approximately 20 filter bags have been used To change the pre mot...

Page 11: ...into the hose to push out the clog Take care not to puncture the hose with the wire Clogs in the Cleaning Wand Active Wand Figure 15 Remove attachment hose 12 from the cleaning wand 15 by pressing the...

Page 12: ...ot fully closed 2 Bag not inserted properly 3 Microfilter not properly inserted 1 Cleaning wand not properly inserted SOLUTION 1 Release handle catch push handle down close handle catch 2 Use another...

Page 13: ...0 5424GS Retaining ring 21 51115HG Internal cover cpl 22 1823HG Attachment clip light gray 23 51150HG Bag housing cpl light gray 24 5084 Spring for locking rod 25 51103GS Bag housing locking catch gra...

Page 14: ...r h light gray gray black 125 2869HG Rubbing plate light gray 126 2868OR Access door incl pos 127 128 127 5303 Access door axle 128 5304 Access door spring 129 2861 Pile adjustment axle 130 5174HG Pi...

Page 15: ...ht gray gray black 125 2869HG Rubbing plate light gray 126 2868OR Access door orange incl pos 127 128 127 5303 Access door axle 128 5304 Access door spring 129 2861 Pile adjustment axle 130 5174HG Pil...

Page 16: ...16 NOTES...

Reviews: