Service manual
R E P A I R
Tools and repair accessories
With the following tools, all described disassembly and repair work can be done:
Repair work without disassembling the machine
Without disassembling the machine, you can clean, replace or repair the following parts:
•
Water tank (pos. 6)
•
Capsule holder (pos. 17)
•
Injector plate (pos. 19)
•
Drip tray (pos. 13) and drip grid (pos. 14)
Cleaning or replacing injector plate, deblocking of injector
Solid residues in the water circuit can block the injector completely. An example is the
development of calcium particles if the machine is not descaled periodically. Therefore
this error appears during descaling frequently.
A pin-torx screw
head looks like this:
Tools
Applications
Torx screwdriver for security screws,
Pin-TX 10
Fastening screws for
- extraction head
- side panels / water tank connector
Phillips screwdriver no. 1
Fastening screw of fuse holder on thermoblock.
Screwdriver with blade width 4 mm
To open latches and snap connections
Flat nose pliers
Flat receptacles, hose clips, filter element of
water tank connector
Fork wrench no. 12
Adjustable pump connector
Cutter (stanley knife)
Cut new pressure hoses to length.
Cutting pliers
To cut cable ties on pressure hoses and H-
connector
Small hammer
Clamp spring (NTC temperature sensor)
Piercer
Pointed pliers
NTC temperature sensor
Heat conducting paste
1.
Remove water tank (pos. 3).
2.
Remove capsule holder (pos. 17).
3.
Switch off and unplug machine.
4.
Take cleaning needle out of support.
3
17
19