LRX 2151
Mono-phase electronic exchange, for the automation of gates
with incorporated receiver.
- Mod.
LG 2151
:
Without radio Receiver
- Mod.
(
LRQ 2151 )
:
30,875MHz
- Mod.
(
LR 2151 )
:
306
MHz
- Mod.
(
LR 2151/330 )
:
330
MHz
- Mod.
(
LR 2151/418 )
:
418
MHz
- Mod.
LRS 2151
:
433,92 MHz
- Mod.
LRS 2151 SET
: Narrow band
433,92 MHz
( )
This product is destined only for countries in which this use
is allowed.
T
ECHNICAL
D
ATA
- Power supply:
230VAC 50-60Hz 8W Max
- Flashing light output:
230VAC 500W Max
- Motor output:
230VAC 500W Max
- Aux. power output:
24VAC 5W Max
- Radio receiver:
refer to type
- Op. transmitters:
12-18 Bit or Rolling Code
- TX max. codes in memory
63 different codes
- Working temperature:
-20÷85°C
- Dimension of panel:
110x150x75mm
- Degree of panel protection:
( ABS V-0 ) IP 55
T
ERMINAL
B
OARD
C
ONNECTION
CN1
1: 230VAC input.
2: 230VAC input.
3: 230VAC flash input.
4: 230VAC flash input.
5: Opening 1 motor output.
6: Common 1 motor output.
7: Closing 1 motor output.
8: Opening 2 motor output.
9: Common 2 motor output.
10: Closing 2 motor output.
T
ERMINAL
B
OARD
C
ONNECTION
CN2
1: 24VAC 5W service feed output.
2: 24VAC 5W service feed output.
3: Open-close push button input (NA).
4: Common GND input.
5: Safety device input (NC).
6: Aerial earth input.
7: Aerial hot pole.
O
PERATING
C
HARACTERISTICS
Selection of Automatic operation or Step by step
operation :
The centre in its default setting shows the automatic working
function set. To set the step by step function: press the MODE
button continuously for 5 seconds, when all the signalling
Leds are flashing, the programming is stored. If on the other
hand, the memorized function is to be removed, follow the
same programming procedure or follow the RESET
procedure.
Automatic operation:
By using either the radio control (led CODE on) or the low
tension button panel (PUL) to operate the gates, commands
will have the following effect: the first command impulse
activates the opening mechanism until time expiry of the
timing motor or until the gate is fully opened, the second
command impulse closes the gate, if a command impulse is
received before the activation of the limit switch, the direction
of movement of the mechanism will be
reversed
whether
engaged in opening or closing operations.
Step by step operation:
By using either the radio control (led CODE on) or the low
tension button panel (PUL) to operate the gates, commands
will have the following effect: the first command impulse
activates the opening mechanism until time expiry of the
timing motor or until the gate is fully opened, the second
command impulse closes the gate, if a command impulse is
received before the activation of the limit switch, the direction
of movement of the mechanism will be
halted
whether
engaged in opening or closing operations.
Automatic closing
The control board may be set up automatically to close the
gates.
The set-up procedure is described under the instruction for
setting the delay period.
Safety device
The control board allows for the connection and control of
Photocells, Tyre sensors (NC).
Command from these devices are ignored during opening
whilst the gate is closing they will reverse the direction of
movement.
If not used the terminals must be jumped.
Electronic clutch
The control is equipped with an adjustable electronic clutch,
using Trimmer VR1. To adjust, move Trimmer VR1 until the
device moves, but can still be blocked by an obstacle (for
example, the test can be carried out by blocking the device
with the hands).
Functioning of the Flasher
The panel board is powered by an output for the use of a
flasher 230VAC. Its function is conditioned by the movement of
the motor and the automatic closure that when inserted
enables the flash even during a pause.
P
ROGRAMMING
SEL button:
selects the type of function to be memorised, the
selection is indicated by a flashing Led.
By repeatedly pressing the button it is possible to choose the
desired function. The selection will remain active for 10
seconds indicated by a flashing Led, if no other operations are
executed during this period, the control board will return to its
previous state.
SET button:
programmes the information relative the type of
function previously selected with the SEL button.
Led Reference
Led off
Led on
1) CODE
No code
Code activated
2) T. MOT.
Unlimited timing
Programmed delay
3) T. PAUSE
No automatic close With automatic close
4) RIT. ANTE AP No wing delay
Programmed delay
5) RIT. ANTE CH No wing delay
Programmed delay
1) CODE:
(Radio control code)
The board allows the memorisation up to 63 radio commands
having different codes, which are either fixed or rolling code.
Programming:
The transmission code is programmed in
the following manner: press the SEL button until the CODE led