4
Rev. 1.3 11/03
flashes, immediately transmit the pre-selected code with the
desired remote control, in the moment in which the led CODE
remains accessible, the programming, will be complete. In
the case that all 63 codes have been memorised repeating
the operation of programming, all the 5 Led will begin to flash
very quickly signalling that no further mem orisation is
possible.
Programming through Radio command:
This procedure, consents to enable the programming, without
direct intervention of the SEL task on the panel, but executing
the operation at a distance, allows the programming of
transmission codes without the having to use the SEL button
on the central direct.
The ability of programming is executed in the following
manner: send in a continuous manner for max. 10 seconds
the codes of the radio command previously memorised, at the
same time the panel will enter into programming mode as
explained above.
Ability of programming through Radio command:
The panel is furnished by the builder with the radio command
disabled, if you wish to enable the function, proceed in the
following manner: the panel board is powered by an output of
230VAC, keeping the SELL task pressed, at the same time
you will obtain a brief flashing of all the Leeds and the
programming will be complete.
If you wish to disable the function previously enabled, repeat
the operation or follow the RESET procedure.
Cancellation:
All the transmission codes are cancelled in
the following manner: press the SEL button until the CODE led
flashes, then press the SET button and the CODE Led will be
turned off and the cancellation will be com pleted.
2) T. MOT.:
(Programming. the motor operating time max. 4
minutes)
The control unit is factory supplied with a working time motor
predefined equal to 30 sec.
If a reprogramming of the motor operating time is needed, it
must be effected through the closed frame in the following
manner: set the SEL button on the T. MOT. flashing led, then
continuously press the SET button, the rolling shutter will start
the opening; when you have reached the required height,
release the SET button key and at the same time the motor
time storage will be completed and the T. MOT. Led will
remain lit and fixed. If you want an infinite motor time, using
the SEL task when the Led T. MOT. is flashing press for less
than 1 second the SET button, at the same time the Led will
shut off and the operation will be completed.
3) T. PAUSE:
(
Maximum programmed automatic wing closing
4 minutes)
The manufacturer furnishes the board with an automatic
closure (pause time equal to 15 sec.). If a reprogramming of
the automatic closing time is needed, it must be effected in
closed frame in the following manner: press the SELL button
until the T. PAUSE led flashes, then press and hold down the
SET button for a period equal to the desired pause interval
between closing and opening operations, at the expiry of the
desired time leave the SET button, at the same time the
memorisation of automatic closing time will be determined
and the Led T. PAUSE will be lit.
If decided not to have the automatic closing, take position on
the flash of the Led T. PAUSE after press the SET task for less
than a second, at the same time the Led will shut off and the
operation will be concluded.
4) DELAY IN WING OPENING:
(programmed wing delay 15 sec.
max.)
The manufacturer furnishes the panel if chosen the
automation of 2 motors with a delay in wing opening equal to
3 seconds (del. MOTOR 2).
If a reprogramming of the delay is needed in relation to its
opening, it must be effected during close frame in the
following manner: take position on the SEL, task when the led
WING DELAY OP. is flashing, then press in continuous
manner the SET task for as long as the time desired, release
the SET task, at the same time the memorisation of the delay
will be determined and the Led DELAY WING OP. will be fixed.
If desired not to have a delay in wing opening, take position on
the Led DELAY WING OP. then press SET task for less than a
second, at the same time the Led will shut off and the
operation will conclude.
5) DELAY IN WING CLOSING:
(programmed wing delay 15 sec.
max.)
The manufacturer furnishes the panel if chosen the
automation of 2 motors with a delay in wing closing equal to 3
seconds (del. MOTOR 1).
If a reprogramming of the delay is needed in relation to its
closing, it must be effected during close frame in the following
manner: take position on the SEL, task when the led WING
DELAY CL. is flashing, then press in continuous manner the
SET task for as long as the time desired, release the SET
task, at the same time the memorisation of the delay will be
determined and the Led DELAY WING CL. will be fixed. If
desired not to have a delay in wing closing, take position on
the Led DELAY WING CL. then press SET task for less than a
second, at the same time the Led will shut off and the
operation will conclude.
R
ESET
If it necessary to reset the program board to its default values,
that is with no memorised data, press both SEL and SET
buttons continuously, all the
RED
LEDs will flash at once.
I
MPORTANT NOTICE FOR THE INSTALLER
−
In order for the receiving part of the radio to function
correctly, in cases where two or more centres are used, it is
advisd to install them at a distance of at least 3 metres from
each other.
−
The centre must not have any type of sectioning
mechanism from the electrical line 230 Vac; it is therefore
the responsibility of the installer to see the installation of a
sectioning device within the plant.
−
The fixing of the electricity supply cables and their
connection, must be guaranteed by means of the assembly
of the cable presses which are provided as “optional”.
−
The input, which is labelled as normally closed (NC),
must be jumped if not used!!