background image

P3

Motor Placement

The motors are to be located on both sides 

of seat back leaving the spine area open. It is 

recomended that a set of motors are located 

below the belt line and then stacked.  The 

motors should not be positioned in the 

shoulder blade, neck or head area. To 

begin the installation, locate the 

massage areas and mark the positions 

(tape) while sitting on the seat.  This will 

reference the locations when the cover

is removed.

1. Locate motor placement on seat back.
2. Remove seat cover and locate and verify motor placement.
3. Trace the motor on the foam, cut out the foam and set motor in cavity 
4. Pass the motor wire through the foam and attach to the distribution box. 
5. Connect all wires and test the system and motors
6. Adhere motors into the foam
7. Place 1/4" foam over the motors and cavity if necessary
8. Instal the connection box into the seat back and tie any loose wires.
9. Check placement of boxes as not to interfere with lumbar/recliner
10. Run power wire to 12 volt supply and test system
11. Re-cover the seat back.
12. Place control wand in vehicle and test 

Options:
3A. Cut a slit into the foam, create a cavity with your fingers and slip motors into place.   

This may create a lump in the foam but it will enhance the massage effect

21

20

30

31

40 41

Summary of Contents for SCS6MC

Page 1: ...Revitalizer Massage Installation Manual SCS6MC Seat Comfort Systems www seatcomfort com Seat Comfort Systems...

Page 2: ...iable for any damage due to improper installation All steps explained in this manual are to be followed with great care Installation has to be performed by qualified personnel only Improper installati...

Page 3: ...Trace the motor on the foam cut out the foam and set motor in cavity 4 Pass the motor wire through the foam and attach to the distribution box 5 Connect all wires and test the system and motors 6 Adhe...

Page 4: ...apply into the foam cavity and then place motor into foam cavity and gently pull the motor wires to insure a light fit Apply pressure to the top of motors and hold against the foam for 15 seconds A Fo...

Page 5: ...t may interfere with the lumbar or recliner mechanisms Attach the power connector wire to P W below and route the wire with fuse to 12 volt power 20 Zone 6 Upper Back Left 21 Zone 6 Upper Back Right 3...

Page 6: ...1 Run the power harness under the carpet and along the scuff plate toward the fuse box 2 Install the negative wire to ground and secure in place 3 Connect the red wire positive to 12 volt power Fuse H...

Page 7: ...Cycles through 8 programs Time Selects duration of massage Speed Increases or decreases massage intensity 1 Z1 Z2 Z3 Chaos 2 Z1 Z2 Z3 Wave 3 Z1 Z2 Z3 Wave with intensity low to high 4 Z1 and Z3 Z2 Cri...

Page 8: ...nstallation misuse neglect accident or customer abuse No person or representative is authorized to assume for the Company any liability other than expressed herein in connection with the sale of this...