background image

3

CONTENTS

Safety ..............................................................................................2

Warranty/Introduction...................................................................3

Pump Performance ........................................................................3

Major Components......................................................................3-4

Piping .............................................................................................4

Electrical......................................................................................5-6

Installation......................................................................................7

Operation .......................................................................................7

Maintenance ................................................................................8-9

Helpful Hints ..................................................................................9

Repair Parts .............................................................................10-11

Troubleshooting Guide ................................................................12

INTRODUCTION

We suggest you take a few minutes to read the instructions con-
tained in this manual before installing and using your pump. This
will help you obtain the full benefits of the quality and convenience
built into this equipment. It will also help you avoid any needless
service expense resulting from causes beyond our control which
naturally cannot be covered in our warranty.

1. Read the Owners Manual and Rules for Safe Operation and

Installation Instructions carefully. Failure to follow these Rules
and Instructions could cause serious bodily injury, and/or prop-
erty damage.

2. Check your local electrical wiring codes before installation. If

your local codes are not followed, your pump will not work to
its full rated capacity. If in doubt, contact your local Power
Company.

3. Be certain your pump installation meets all local plumbing,

pump and well codes.

4. While installing the pump, always keep the well covered to pre-

vent leaves and foreign matter from falling into the well and con-
taminating the water and/or causing possible serious damage to
the mechanical operation of the pump.

5. Always test the well water for purity before using. Check with

local health department for testing procedure.

6. Before installing or servicing your pump, BE CERTAIN pump

power source is disconnected.

7. Be sure your pump electrical circuit is properly grounded.

8. Complete pump and piping system MUST be protected against

below freezing temperature. Failure to do so could cause severe
damage and voids the Warranty.

9. Make sure the line voltage and frequency of the electrical circuit

supply agree with the motor wiring. If motor is dual voltage
type, BE SURE it is wired correctly for your power supply.

10. The correct fusing and wiring sizing is essential to proper motor

operation. Recommended fusing and wire size data is in the
manual.

FULL ONE YEAR WARRANTY ON CRAFTSMAN

®

WELL PUMPS

For one year from the date of purchase, Sears will repair or replace this pump, free of charge, if defective in material or workmanship.

LIMITED WARRANTY ON CRAFTSMAN

®

PROFESSIONAL HYDROGLASS

®

WELL PUMPS

After one year and through three years from the date of purchase, Sears will furnish, free of charge, a replacement part for any defective part.
You pay for labor.

LIMITED WARRANTY ON CRAFTSMAN

®

HYDROGLASS

®

WELL PUMP

After one year and through two years from the date of purchase, Sears will furnish, free of charge, a replacement part for any defective part. 
You pay for labor.
This warranty does not cover repairs or replacement parts necessary because of abuse or negligence including failure to install, adjust and 
operate this pump according to the instructions in the owner’s manual.

LIMITATION OF  LIABILITY

SEARS WILL NOT BE LIABLE FOR LOSS OR DAMAGE TO PROPERTY OR ANY INCIDENTAL OR CONSEQUENTIAL LOSS OR EXPENSE FROM
PROPERTY DAMAGE DUE DIRECTLY OR INDIRECTLY FROM THE USE OF THIS PRODUCT.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply
to you.
WARRANTY SERVICE IS AVAILABLE BY SIMPLY CONTACTING THE NEAREST SEARS SERVICE CENTER/DEPARTMENT IN THE UNITED
STATES.
This warranty applies only while the product is in use in the United States.
This warranty gives you specific legal rights, and you may also have other rights which vary from  state to state.

Sears, Roebuck and Co., Dept. 817 WA, Hoffman Estates, IL 60179

RULES FOR SAFE INSTALLATION AND OPERATION

Summary of Contents for CRAFTSMAN HYDROGLASS 390.2514

Page 1: ...Instructions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Installation Operation Troubleshooting Repai...

Page 2: ...k burn or cause death Ground pump before connecting to power supply Hazardous pressure Install pressure relief valve in discharge pipe Release all pressure on system before working on any component Pe...

Page 3: ...anty 9 Make sure the line voltage and frequency of the electrical circuit supply agree with the motor wiring If motor is dual voltage type BE SURE it is wired correctly for your power supply 10 The co...

Page 4: ...he pump is over well This will be less if pump is offset from the well Both figures are for sea level The maximum lift of any pump decreases with the elevation above sea level This decrease is at the...

Page 5: ...the one at right Dial Type Voltage Selector To change to 115 volts 1 Make sure power is off 2 Turn the dial counter clockwise until 115 shows in the dial window 3 Reinstall the Motor end cover 4 Go t...

Page 6: ...ire at least as large as the power supply wires 3 Connect the ground wire to a grounded lead in a service panel to a metal underground water pipe to a metal well casing at least ten feet 3M long or to...

Page 7: ...ded fittings in the plastic pump If leaks do occur remove the fitting replace the Teflon tape and rewrap with 1 1 2 to 2 turns of Teflon tape and remake the connection 2 Independently support all pipi...

Page 8: ...side with plastic mallet This will insure proper seating of O Ring and clamp E Assemble base mounting bolts Connect pressure switch tub ing and close draincock F Prime pump and turn on power REMOVING...

Page 9: ...e proceed as follows 1 Disassemble pump per instructions on Page 8 2 Turn venturi counterclockwise and remove it The nozzle is now exposed Remove it using a 5 8 hex socket wrench with extension Turn c...

Page 10: ...6 7 8 10 9 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 25A 26 27 28 29 766 1194 To Order Parts in the U S A Call Sears Product Service 1 800 366 7278 To Order Parts outside the U S A Call Your local...

Page 11: ...7 8 5 Required U43 21SS 8 Star Washer 5 Required 10 C19 54SS C19 54SS Clamp Tank Body 11 U9 201 U9 201 O Ring Venturi 1 3 8 x 1 1 8 x 1 8 12 N32P 66 N32P 66E Venturi 13 N34P 19 N34P 17 Nozzle 14 N76...

Page 12: ...h plastic pipe where possible otherwise with point 3 immediately limed causing excess friction new steel pipe above 3 Offset piping is too small in size 3 Use larger offset piping Pump pumps water 1 P...

Page 13: ...13...

Page 14: ...14...

Page 15: ...15...

Page 16: ...all 9 am 5 pm Monday Saturday 1 800 827 6655 M A I N T E N A N C E A G R E E M E N T America s Repair Specialists REPAIRSERVICES America s Repair Specialists REPAIRSERVICES America s Repair Specialist...