I. Screw impeller on shaft (clockwise) while holding

shaft with 7/16” open end wrench on shaft flats. This
will automatically locate seal in place. See Figure 9.

J. Remount diffuser on seal plate. 

Be sure

diffuser is

right side up as follows (see Figures 10 and 11).

a. Rib next to priming hole should be at six o’clock

position;

b. Part number (N1-28P) should be between nine

o’clock and ten o’clock.

c. Both mounting screws must engage screw holes

in seal plate. See Figure 10.

d.

Be sure

rubber pad (Figure 10; Key No. 8, Page

11) stays in place on top of diffuser.

Installing Copper Insert

NOTE:

If the copper insert (Key No. 4, Page 11) moves or

shifts during seal removal, it should be removed and rein-
stalled.

1. Remove copper insert as shown in Figure 12. do not de-

form.

2. Replace copper insert:

A. Clean off surplus Permatex* from around insert cav-

ity. Be careful not to scratch or mark the machined
bore. It is important that this area be clean no no old
Permatex lodges behind the new insert and causes im-
proper seating.

B. Place a small amount of No. 2 non-hardening

Permatex on surface of insert as shown. Smooth out
with finger. See Figure 13.

* “Permatex” is a registered trademark of Permatex Co. Inc.

8

Figure 9

Figure 10

Figure 11

Figure 12

Summary of Contents for CRAFTSMAN HYDROGLASS 390.250284

Page 1: ...Instructions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Installation Operation Troubleshooting Repa...

Page 2: ...izing is essential to proper motor operation Recommended fusing and wire size data is in the manual Page 5 11 Pump water only with this pump 12 Periodically inspect pump and system components Motor no...

Page 3: ...ot valve and strainer should be installed for easy priming It should be five to ten feet below the lowest level to which the water will drop while pump is operating pumping water level The strainer sh...

Page 4: ...pump is very similar to cast iron pumps We ask however that you keep the following points in mind IMPORTANT Use teflon tape supplied with the pump for making all threaded connections to the pump it s...

Page 5: ...switch as shown in Figure 4 5 FIGURE 4 Motor wiring connections through Pressure Switch Match motor voltage to line voltage Your Motor Terminal Board under the motor end cover and Pressure Switch look...

Page 6: ...o a point below the freeze line To drain an air volume control AVC remove the tubing from it and turn the AVC upside down This will permit any water in the AVC to drain into tank Disassembly and Assem...

Page 7: ...eum jelly or de tergent solution C With finger pressure press firmly and squarely into cavity Polished face of seat faces inside of pump If seat will not locate properly place cardboard washer over po...

Page 8: ...Page 11 stays in place on top of diffuser Installing Copper Insert NOTE If the copper insert Key No 4 Page 11 moves or shifts during seal removal it should be removed and rein stalled 1 Remove copper...

Page 9: ...ction as the dislodging tool was inserted 4 Replace nozzle and venturi Do not overtighten 5 Reassemble per pump instructions on Page 6 HELPFUL HINTS How to Handle a Gaseous Well In some areas well wat...

Page 10: ...es not 1 Water level in well is lower than 1 A deep well jet pump may be needed over 20 ft to water deliver water to full estimated capacity Also 2 Steel piping if used is corroded or 2 Replace with p...

Page 11: ...C78 41T 1 Pipe Plug 1 8 NPT 14 U111 212T 2 90 Hose Barb 15 U37 669P 1 Switch Tube 16 J20 18 1 Gasket 17 N76 29P 1 Pump Body Jet Insert 18 U30 742SS 4 Capscrew 10 16 19 N34P 19 1 Nozzle 45 20 N32P 66 1...

Page 12: ...5 pm Monday Saturday 1 800 827 6655 M A I N T E N A N C E A G R E E M E N T America s Repair Specialists REPAIRSERVICES America s Repair Specialists REPAIRSERVICES America s Repair Specialists REPAIR...

Reviews: