background image

ELECTRICAL

Hazardous voltage. Can shock, burn, or

kill. Connect ground wire before connecting power
supply wires. Use the wire size (including the ground
wire) specified in the wiring chart.

If possible, connect

the pump to a separate branch circuit with no other appli-
ances on it. 

Explosion hazard. Do not ground to a gas

supply line.

WIRING CONNECTIONS

Fire hazard.

Incorrect voltage can cause a

fire or seriously damage the motor and voids the warranty.
The supply voltage must be within ±10% of the motor name-
plate voltage.

NOTICE: 

Dual-voltage motors are factory wired for 230

volts. If necessary, reconnect the motor for 115 volts, as
shown. Do not alter the wiring in single voltage motors.

Install, ground, wire, and maintain your pump in compli-
ance with the National Electrical Code (NEC) or the
Canadian Electrical Code (CEC), as applicable, and with all
local codes and ordinances that apply. Consult your local
building inspector for code information.

Connection Procedure:

1. Connect the ground wire first as shown in Figure 4. The

ground wire must be a solid copper wire at least as large
as the power supply wires.

2. There must be a solid metal connection between the pres-

sure switch and the motor for motor grounding protec-
tion. If the pressure switch is not connected to the motor,
connect the green ground screw in the switch to the
green ground screw under the motor end cover. Use a
solid copper wire at least as large as the power supply
wires.

3. Connect the ground wire to a grounded lead in a service

panel, to a metal underground water pipe, to a metal well
casing at least ten feet (3M) long, or to a ground electrode
provided by the power company or the hydro authority.

4. Connect the power supply wires to the pressure switch

as shown in Figure 4. 

5

FIGURE 4: Motor wiring connections through Pressure Switch. Match motor voltage to line voltage.

Your Motor Terminal Board (under the motor end cover)
and Pressure Switch look like one of those shown below.
Convert to 115 Volts as shown. Do not change motor wiring

if line voltage is 230 Volts or if you have a single voltage
motor. Connect power supply as shown for your type of
switch and your supply voltage.

Move plug to change voltage.

115 V

230 V

Power Supply Wires

L

1

L

2

23

0

115

L

1

L

2

23

0

115

L

1

L

2

23

0

115

Grounding Point

3781 1000

230 Volt to 115 Volt Conversion, Plug-in Type: 

230 Volt to 115 Volt Conversion, Plug-in Type: 

Pull plug 
straight
out from 
terminal
board.

1.

1.

2.

2.

Plug in again
with arrow 
on plug 
pointing to
'115 Volts'.

A

L1

2

3

0

 

V

o

lt

s

1

1

5

 

V

o

lt

s

A

L1

2

3

0

 

V

o

lt

s

1

1

5

 

V

o

lt

s

Ground
Screw

Clamp the power cable to prevent strain 
on the terminal screws.

Connect the green (or bare copper) ground wire 
to the green ground screw.

Motor wires connect here.

Clamp the power cable to prevent strain 
on the terminal screws.

Connect the green (or bare copper)  ground wire 
to the green ground screw.

Motor wires connect here.

3187 0398

Power supply wires connect here. 
230 Volt: Connect 2 hot wires (black and red)
here and cap the white (neutral) wire. It does
not matter which wire goes to which screw. 
115 Volt: Connect one hot wire (black or red)
to one of these screws (it doesn't matter 
which one). Connect the white (neutral) wire 
to the other screw. Cap any remaining 
black or red wires.

Power supply wires connect here. 
230 Volt: Connect 2 hot wires (black and red)
here and cap the white (neutral) wire. It does
not matter which wire goes to which screw. 
115 Volt: Connect one hot wire (black or red)
to one of these screws (it doesn't matter 
which one). Connect the white (neutral) wire 
to the other screw. Cap any remaining 
black or red wires.

Disconnect power before working on pump, motor, pressure switch, or wiring. 

Summary of Contents for CRAFTSMAN HYDROGLASS 390.250284

Page 1: ...Instructions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Installation Operation Troubleshooting Repa...

Page 2: ...izing is essential to proper motor operation Recommended fusing and wire size data is in the manual Page 5 11 Pump water only with this pump 12 Periodically inspect pump and system components Motor no...

Page 3: ...ot valve and strainer should be installed for easy priming It should be five to ten feet below the lowest level to which the water will drop while pump is operating pumping water level The strainer sh...

Page 4: ...pump is very similar to cast iron pumps We ask however that you keep the following points in mind IMPORTANT Use teflon tape supplied with the pump for making all threaded connections to the pump it s...

Page 5: ...switch as shown in Figure 4 5 FIGURE 4 Motor wiring connections through Pressure Switch Match motor voltage to line voltage Your Motor Terminal Board under the motor end cover and Pressure Switch look...

Page 6: ...o a point below the freeze line To drain an air volume control AVC remove the tubing from it and turn the AVC upside down This will permit any water in the AVC to drain into tank Disassembly and Assem...

Page 7: ...eum jelly or de tergent solution C With finger pressure press firmly and squarely into cavity Polished face of seat faces inside of pump If seat will not locate properly place cardboard washer over po...

Page 8: ...Page 11 stays in place on top of diffuser Installing Copper Insert NOTE If the copper insert Key No 4 Page 11 moves or shifts during seal removal it should be removed and rein stalled 1 Remove copper...

Page 9: ...ction as the dislodging tool was inserted 4 Replace nozzle and venturi Do not overtighten 5 Reassemble per pump instructions on Page 6 HELPFUL HINTS How to Handle a Gaseous Well In some areas well wat...

Page 10: ...es not 1 Water level in well is lower than 1 A deep well jet pump may be needed over 20 ft to water deliver water to full estimated capacity Also 2 Steel piping if used is corroded or 2 Replace with p...

Page 11: ...C78 41T 1 Pipe Plug 1 8 NPT 14 U111 212T 2 90 Hose Barb 15 U37 669P 1 Switch Tube 16 J20 18 1 Gasket 17 N76 29P 1 Pump Body Jet Insert 18 U30 742SS 4 Capscrew 10 16 19 N34P 19 1 Nozzle 45 20 N32P 66 1...

Page 12: ...5 pm Monday Saturday 1 800 827 6655 M A I N T E N A N C E A G R E E M E N T America s Repair Specialists REPAIRSERVICES America s Repair Specialists REPAIRSERVICES America s Repair Specialists REPAIR...