background image

2

INDICE DE MATERIAS

INTRODUCCION/GARANTIA    . . . . . . . . . . . . . . . . . . . . . . .2
SEGURIDAD   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
INSTALACION   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
FUNCIONAMIENTO  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
INFORMACIÓN ELÉCTRICA  . . . . . . . . . . . . . . . . . . . . . . .4-5
MANTENIMIENTO  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
SERVICIO   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-7
REPUESTOS   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

INTRODUCCION

Se ruega leer nuestras instrucciones antes de instalar y usar su
nueva bomba.  De esta manera logrará un mejor rendimiento y
buen servicio.  Además le ayudará a evitar costos de servicio in-
necesarios resultantes de causas que están fuera de nuestro con-
trol y que no pueden ser cubiertas por nuestra garantía.

Lea y siga cuidadosamente todas las instrucciones de se-
guridad indicadas en este manual o en la bomba.

Este símbolo es una señal de alerta. 

Cuando vea este sím-

bolo en su bomba o en este manual, busque alguna de las ad-

vertencias que se indican a continuación y manténgase alerta pues
ellas indican que existe la posibilidad de sufrir una lesión personal.

advierte acerca de riesgos que si son ignorados

causarán

lesiones personales graves, muerte o daños materiales.

advierte acerca de riesgos que si son ig-

norados 

causarán

podrán causar

lesiones personales graves,

muerte o daños materiales.

advierte acerca de riesgos que si son ignorados

causarán

podrán causar

lesiones personales leves, o daños materiales.

La palabra 

AVISO

indica instrucciones especiales que son impor-

tantes pero que no constituyen riesgos.

Las bombas de sumidero eléctricas por lo regular duran muchos
años sin sufrir problemas de servicio, cuando son instaladas, man-
tenidasy usadas correctamente. Sin embargo, las situaciones
inusuales (interrupción del suministro eléctrico que va a la bomba,
tierra o suciedad en el sumidero, inundación superior a la capaci-
dad de la bomba, fallas eléctricas y mecánicas, etc.), pueden evitar
que su bomba funcione como acostumbra. Para evitar posibles
daños causados por el agua debido a inundaciones, consulte su es-
tablecimiento Sears local sobre la instalación de una bomba de sum-

idero secundaria o una bomba de sumidero de reserva operada a
batería. Consulte la sección “Servicio”, Página 6, para información
sobre problemas comunes de la bomba de sumidero y soluciones.

1. Antes de instalar la bomba, leer cuidadosamente las instruc-

ciones de seguridad a fín de evitar daños materiales o lesiones
personales graves.

2. Al instalar la bomba respetar todos los códigos eléctricos  locales

y/o nacionales.

3. 

Para evitar choques eléctricos mor

tales, siga las instrucciones que se indican a con-
tinuación cuando sea necesario reparar la bomba:

A. Desconectar la corriente eléctrica hacia la caja del

tomacorriente antes de desenchufar el cordón de la
bomba. 

Una vez desenchufada, dejar que la bomba se enfríe

durante unos 20 minutos antes de intentar trabajar en ella.
Los motores modernos pueden funcionar a alta temperatura.

B. Tener mucho cuidado cuando se cambian los fusibles.

A fin de reducir la posibilidad de choques eléctricos mortales,

NO

pararse sobre agua ni colocar el dedo en el enchufe del

fusible.

C. Poner a tierra 

la caja del tomacorriente eléctrico.

D.Para enchufar el cordón, usar solamente un requiere un

ramal individual con el tomacorrientes puesto a tierra
protegido con un interruptor del circuito de pérdida a
tierra.

ADVERTENCIA

PRECAUCIÓN

ADVERTENCIA

PELIGRO

INFORMACION GENERAL SOBRE SEGURIDAD

GARANTÍA TOTAL DE CINCO AÑOS DE CRAFTSMAN

Este producto se garantiza POR CINCO AÑOS a partir de la fecha de compra, contra defectos de materiales y
mano de obra. Un producto defectuoso será reparado gratuitamente en su casa o reemplazado gratuitamente si la
reparación no fuese posible.

Para detalles sobre la cobertura de la garantía para obtener una reparación o un reemplazo gratuito,
visite el sitio web: www.craftsman.com 

Esta garantía quedará anulada si este producto se ha usado para proveer servicios comerciales o si ha sido arren-
dado a otra persona. 

Esta garantía le otorga derechos legales específicos y puede que también tenga otros derechos, los cuales varían de

un Estado al otro.

Sears Brands Management Corporation, Hoffman Estates, IL 60179

Summary of Contents for Craftsman 390.305001

Page 1: ... Rules and Operating Instructions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Installation Electrical Maintenance Repair Parts PROFESSIONAL SUBMERSIBLE SUMP PUMP Form No CR907 8 20 10 ...

Page 2: ...age due to flooding consult your local Sears store about installing a secondary sump pump or a DC backup sump pump See Service Page 6 for information about common sump pump problems and remedies 1 To avoid risk of serious bodily injury and property dam age read safety instructions carefully before installing pump 2 Follow local and or national plumbing and electrical codes when installing pump 3 T...

Page 3: ...cing This pump has not been investigated for use in swimming pool areas This pump is supplied with a grounding conductor and grounding type attachment plug Be certain that it is connected only to a properly grounded ground ing type receptacle Where a 2 prong wall receptacle is encountered it must be replaced with a properly grounded 3 prong receptacle installed in accordance with the National Elec...

Page 4: ...the pump and switch from the electrical power source before doing any maintenance Follow instructions below to install pump with factory mounted switch 1 Be sure automatic float can swing freely through its entire arc without interference from pump piping sump wall or any other object 2 Plug the automatic switch cord into a properly grounded outlet see Electrical Connections Page 4 Plug the pump p...

Page 5: ...air a non operational sump pump Take it to Sears for service by a qualified technician Generator Sizing Below is the minimum Engine Generator Watt rating required to power this pump motor Any additional loads such as lights must be added to the listed load and the generator sized ac cordingly Generators are available at all Sears Stores Pump Minimum Watt Model HP Rating of Generator 390 305001 390...

Page 6: ...take screen b Water may be entering sump faster than the pump can discharge it c Be sure vertical distance from pump discharge outlet to discharge pipe outlet does not exceed maximum vertical pumping distance shown in Specifications below d Be sure discharge pipe is not plugged or frozen TEATHERED SWITCH REPLACEMENT NOTICE Teathered float must be able to swing through its complete arc without inte...

Page 7: ...n Part Number 1 Switch PS117 144P 2 Screw U30 955PS 3 Cord Clip CC0030 13 4 Power Cord PS117 54 TSU 5 Motor Housing 6 Upper Volute PS1 28P 7 Screws U30 920SS 3 Req 8 Impeller PS5 22P 9 Volute Gasket PS20 19 10 Base Plate PS3 29P 11 Cap Screws U30 934ZP 8 Req REPAIR PARTS LIST Quantity ONE unless otherwise noted Not illustrated If motor fails replace entire pump 7 5 4 1 2 3 8 9 10 11 6 ...

Page 8: ...self For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME 1 800 469 4663 Call anytime day or night U S A and Canada www sears com www sears ca Our Home For repair of carry in items like vacuums lawn equipment and electronics call or go on line for the location of your nearest Sears Parts Repair Center 1 800 488 1222 Call anytim...

Page 9: ...as instrucciones antes de comenzar la instalación Conservar este Manual para referencia futura Sears Roebuck and Co Hoffman Estates IL 60179 U S A Instrucciones seguridad Instalación Electricidad Mantenimiento Repuestos BOMBA PROFESIONAL SUMERGIBLE DE SUMIDERO Formulario N CR907 8 20 10 ...

Page 10: ...ecundaria o una bomba de sumidero de reserva operada a batería Consulte la sección Servicio Página 6 para información sobre problemas comunes de la bomba de sumidero y soluciones 1 Antes de instalar la bomba leer cuidadosamente las instruc ciones de seguridad a fín de evitar daños materiales o lesiones personales graves 2 Al instalar la bomba respetar todos los códigos eléctricos locales y o nacio...

Page 11: ...a tierra Asegúrese de que sea conec tada solamente a un tomacorrientes debidamente puesto a tierra Si el tomacorrientes sirve solamente para enchufes de dos clavijas debe ser reemplazado por un tomacorrientes para enchufes de tres clavijas debidamente puesto a tierra insta lado de acuerdo con el Código Eléctrico Nacional y los códi gos y reglamentos locales 15 Proteger el cordón eléctrico de ser d...

Page 12: ...léctrica antes de efectuar algún trabajo de mantenimiento Seguir las instrucciones que se indican a continuación para in stalar la bomba provista con interruptor montado en la fábrica 1 Asegurarse de que el flotador automático pueda desplazarse libremente a través de todo su arco sin interferencia de la bomba de la tubería de la pared del sumidero o de cualquier otro objeto 2 Enchufar el cordón de...

Page 13: ...to cuando se está trabajando en ella NO intente reparar una bomba de agua que no funcione Llévela a Sears para que sea reparada por un técnico calificado Determinación de la Potencia del Generador A continuación se indica la potencia nominal mínima en Watts requerida por el Generador para alimentar el motor de esta bomba Cualquier carga adicional tales como luces se deben agregar a las cargas ante...

Page 14: ... bomba b El agua le puede estar entrando al sumidero en forma más rápida que como puede descargarla la bomba c Be sure vertical distance from pump discharge outlet to dis charge pipe outlet does not exceed maximum vertical pumping distance shown in Specifications below d Asegurarse de que la tubería de descarga no esté obstruida o congelada REEMPLAZO DEL CONMUTADOR ANCLADO AVISO El interruptor de ...

Page 15: ... contrario No se ilustra Si falla el motor reemplace toda la bomba Clave Descripción No de la pieza No de repuesto 1 Conmutador PS117 144P 2 Tornillo U30 955PS 3 Clip del cordón CC0030 13 4 Cordón eléctrico PS117 54 TSU 5 Caja del motor 6 Voluta superior PS1 28P 7 Tornillos U30 920SS 3 req 8 Impulsor PS5 22P 9 Empaquetadura de la voluta PS20 19 10 Placa de base PS3 29P 11 Tornillo prisioneros U30 ...

Page 16: ...self For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME 1 800 469 4663 Call anytime day or night U S A and Canada www sears com www sears ca Our Home For repair of carry in items like vacuums lawn equipment and electronics call or go on line for the location of your nearest Sears Parts Repair Center 1 800 488 1222 Call anytim...

Reviews: