INTRODUCTION

Please read our instructions before you install and use your
new pump; this will help you obtain full value and good ser-
vice from it. It will also help you avoid needless service costs
that result from causes we cannot control and cannot cover
in our warranty.

Carefully read and follow all safety instructions in this
manual or on pump.

This is the safety alert symbol.

When you see this

symbol on your pump or in this manual, look for one

of the following signal words and be alert to the potential
for personal injury!

warns about hazards that 

will 

cause serious

personal injury, death or major property damage if ignored.

warns about hazards that 

will 

or 

can 

cause se-

rious personal injury, death or major property damage if ig-
nored.

warns about hazards that 

will 

or 

can 

cause

minor personal injury or property damage if ignored.

The word 

NOTICE 

indicates special instructions which are

important but not related to hazards.

Electrically powered sump pumps normally give many years
of trouble-free service when correctly installed, maintained,
and used. However, unusual circumstances (interruption of
power to the pump, dirt/debris in the sump, flooding that ex-
ceeds the pump’s capacity, electrical or mechanical failure in
the pump, etc.) may prevent your pump from functioning
normally. To prevent possible water damage due to flooding,

consult your local Sears store about installing a secondary
sump pump or a DC backup sump pump. See “Service”, Page
6, for information about common sump pump problems and
remedies.

1. To avoid risk of serious bodily injury and property dam-

age, read safety instructions carefully before installing
pump.

2. Follow local and/or national plumbing and electrical

codes when installing pump.

3.

To avoid fatal shocks, proceed as fol-

lows if pump needs servicing:

A.Disconnect power to pump outlet box before

pulling pump cord plug.

After plug is pulled, let

pump cool for 20 minutes before attempting to work
on it. Modern motors may operate at high tempera-
tures.

B.

Take extreme care when changing fuses. 

To re-

duce the chance of fatal electrical shocks, 

DO NOT

stand in water or put your finger in the fuse socket.

C.

Ground 

the electrical outlet box.

D.

Use only an individual branch circuit with a
Ground Fault Circuit Interrupter (GFCI) protected
grounded outlet for cord plug.

GENERAL SAFETY INFORMATION

CRAFTSMAN FIVE YEAR FULL WARRANTY

FOR FIVE YEARS from the date of purchase, this product is warranted against any defects in material or 
workmanship. A defective product will receive free in-home repair or free replacement if repair is unavailable.

For warranty coverage details to obtain free repair or replacement, visit the web site: 
www.craftsman.com 

This warranty is void if this product is ever used while providing commercial services or if rented to another 
person. 

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Sears Brands Management Corporation, Hoffman Estates, IL 60179

Summary of Contents for Craftsman 390.305001

Page 1: ... Rules and Operating Instructions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Installation Electrical Maintenance Repair Parts PROFESSIONAL SUBMERSIBLE SUMP PUMP Form No CR907 8 20 10 ...

Page 2: ...age due to flooding consult your local Sears store about installing a secondary sump pump or a DC backup sump pump See Service Page 6 for information about common sump pump problems and remedies 1 To avoid risk of serious bodily injury and property dam age read safety instructions carefully before installing pump 2 Follow local and or national plumbing and electrical codes when installing pump 3 T...

Page 3: ...cing This pump has not been investigated for use in swimming pool areas This pump is supplied with a grounding conductor and grounding type attachment plug Be certain that it is connected only to a properly grounded ground ing type receptacle Where a 2 prong wall receptacle is encountered it must be replaced with a properly grounded 3 prong receptacle installed in accordance with the National Elec...

Page 4: ...the pump and switch from the electrical power source before doing any maintenance Follow instructions below to install pump with factory mounted switch 1 Be sure automatic float can swing freely through its entire arc without interference from pump piping sump wall or any other object 2 Plug the automatic switch cord into a properly grounded outlet see Electrical Connections Page 4 Plug the pump p...

Page 5: ...air a non operational sump pump Take it to Sears for service by a qualified technician Generator Sizing Below is the minimum Engine Generator Watt rating required to power this pump motor Any additional loads such as lights must be added to the listed load and the generator sized ac cordingly Generators are available at all Sears Stores Pump Minimum Watt Model HP Rating of Generator 390 305001 390...

Page 6: ...take screen b Water may be entering sump faster than the pump can discharge it c Be sure vertical distance from pump discharge outlet to discharge pipe outlet does not exceed maximum vertical pumping distance shown in Specifications below d Be sure discharge pipe is not plugged or frozen TEATHERED SWITCH REPLACEMENT NOTICE Teathered float must be able to swing through its complete arc without inte...

Page 7: ...n Part Number 1 Switch PS117 144P 2 Screw U30 955PS 3 Cord Clip CC0030 13 4 Power Cord PS117 54 TSU 5 Motor Housing 6 Upper Volute PS1 28P 7 Screws U30 920SS 3 Req 8 Impeller PS5 22P 9 Volute Gasket PS20 19 10 Base Plate PS3 29P 11 Cap Screws U30 934ZP 8 Req REPAIR PARTS LIST Quantity ONE unless otherwise noted Not illustrated If motor fails replace entire pump 7 5 4 1 2 3 8 9 10 11 6 ...

Page 8: ...self For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME 1 800 469 4663 Call anytime day or night U S A and Canada www sears com www sears ca Our Home For repair of carry in items like vacuums lawn equipment and electronics call or go on line for the location of your nearest Sears Parts Repair Center 1 800 488 1222 Call anytim...

Page 9: ...as instrucciones antes de comenzar la instalación Conservar este Manual para referencia futura Sears Roebuck and Co Hoffman Estates IL 60179 U S A Instrucciones seguridad Instalación Electricidad Mantenimiento Repuestos BOMBA PROFESIONAL SUMERGIBLE DE SUMIDERO Formulario N CR907 8 20 10 ...

Page 10: ...ecundaria o una bomba de sumidero de reserva operada a batería Consulte la sección Servicio Página 6 para información sobre problemas comunes de la bomba de sumidero y soluciones 1 Antes de instalar la bomba leer cuidadosamente las instruc ciones de seguridad a fín de evitar daños materiales o lesiones personales graves 2 Al instalar la bomba respetar todos los códigos eléctricos locales y o nacio...

Page 11: ...a tierra Asegúrese de que sea conec tada solamente a un tomacorrientes debidamente puesto a tierra Si el tomacorrientes sirve solamente para enchufes de dos clavijas debe ser reemplazado por un tomacorrientes para enchufes de tres clavijas debidamente puesto a tierra insta lado de acuerdo con el Código Eléctrico Nacional y los códi gos y reglamentos locales 15 Proteger el cordón eléctrico de ser d...

Page 12: ...léctrica antes de efectuar algún trabajo de mantenimiento Seguir las instrucciones que se indican a continuación para in stalar la bomba provista con interruptor montado en la fábrica 1 Asegurarse de que el flotador automático pueda desplazarse libremente a través de todo su arco sin interferencia de la bomba de la tubería de la pared del sumidero o de cualquier otro objeto 2 Enchufar el cordón de...

Page 13: ...to cuando se está trabajando en ella NO intente reparar una bomba de agua que no funcione Llévela a Sears para que sea reparada por un técnico calificado Determinación de la Potencia del Generador A continuación se indica la potencia nominal mínima en Watts requerida por el Generador para alimentar el motor de esta bomba Cualquier carga adicional tales como luces se deben agregar a las cargas ante...

Page 14: ... bomba b El agua le puede estar entrando al sumidero en forma más rápida que como puede descargarla la bomba c Be sure vertical distance from pump discharge outlet to dis charge pipe outlet does not exceed maximum vertical pumping distance shown in Specifications below d Asegurarse de que la tubería de descarga no esté obstruida o congelada REEMPLAZO DEL CONMUTADOR ANCLADO AVISO El interruptor de ...

Page 15: ... contrario No se ilustra Si falla el motor reemplace toda la bomba Clave Descripción No de la pieza No de repuesto 1 Conmutador PS117 144P 2 Tornillo U30 955PS 3 Clip del cordón CC0030 13 4 Cordón eléctrico PS117 54 TSU 5 Caja del motor 6 Voluta superior PS1 28P 7 Tornillos U30 920SS 3 req 8 Impulsor PS5 22P 9 Empaquetadura de la voluta PS20 19 10 Placa de base PS3 29P 11 Tornillo prisioneros U30 ...

Page 16: ...self For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME 1 800 469 4663 Call anytime day or night U S A and Canada www sears com www sears ca Our Home For repair of carry in items like vacuums lawn equipment and electronics call or go on line for the location of your nearest Sears Parts Repair Center 1 800 488 1222 Call anytim...