background image

OPERATION

PRIMING THE PUMP

NOTICE:

‘Priming’ refers to the pump expelling all air in the

system and beginning to move water from its source out into
the system. It does not refer only to pouring water into the
pump (although pouring water in is usually the first step).

NOTICE: NEVER run pump dry.

Running pump without

water in it will damage seals and can melt impeller and dif-
fuser. To prevent damage, 

fill pump with water before

starting.

1. Remove priming plug (Figure 7). 

2. Make sure suction and discharge valves and any hoses on

discharge side of pump are open.

3. Fill pump and suction pipe with water.

4. Replace priming plug, using Teflon tape on thread;

tighten plug.

NOTICE:

If a priming tee and plug have been provided

for a long horizontal run, be sure to fill suction pipe
through this tee and replace plug. (Don’t forget to Teflon
tape the plug.)

5. Start pump: water should be produced in 10 minutes or

less, the time depending on depth to water (not more
than 20’) and length of horizontal run (10’ of horizontal
suction pipe = 1’ of vertical lift due to friction losses in
the pipe).

If no water is produced within 10 minutes, stop pump,
release all pressure, remove priming plug, refill and try
again.

Hazardous pressure and risk of explo-

sion and scalding. If pump is run continuously at no
flow (that is, with discharge shut off or without prim-
ing), water may boil in pump and piping system.
Under steam pressure, pipes may rupture, blow off of
fittings or blow out of pump ports and scald anyone
near.

To prevent explosion, do the following:
A. Be sure discharge (valve, pistol grip hose nozzle, etc.) is

open whenever pump is running.

B. If pump fails to produce water when attempting to prime,

release all pressure, drain pump and refill with cold water
after every two attempts.

C. When priming, monitor pump and piping temperature. If

pump or piping begin to feel warm to the touch, shut off
pump and allow system to cool off. Release all pressure
in system and refill pump and piping with cold water.

7

P

867 0494

P

858 0494

1117 0993

Figure 8 – Fill Pump Before Starting

Figure 10 – Do Not Run Pump With Discharge
Shut Off

Figure 7 – Remove Priming Plug

Figure 9 – Run Ten Minutes Or Less

Summary of Contents for CRAFTSMAN 390.262453

Page 1: ...ore First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Installation Electrical Maintenance Repair Parts PRINTED IN...

Page 2: ...isconnect electrical power source before installing or working on pump 6 Ground pump with a ground wire run from grounding lug on motor to a grounded lead in the service panel 7 Line voltage and frequ...

Page 3: ...in a booster applica tion 1 Lake Chemical Co Chicago Illinois NOTICE Use the installation method below which matches your well type CASED WELL INSTALLATION 1 Inspect foot valve to be sure it works fr...

Page 4: ...ping Do not increase pipe size by stages 2 When the pump is set away from the points of water use the discharge pipe size should be increased to reduce pressure losses caused by friction Up to 100 run...

Page 5: ...pe on all male threads being attached to pump 4 Tighten joints hand tight plus 1 1 2 turns Do not over tighten NOTICE Install pump as close to water source as possible Long piping runs and many fittin...

Page 6: ...oil and chemicals 7 Connect current carrying conductors to terminals L1 and L2 under motor canopy When replacing motor check wiring diagram on motor nameplate against Figure 6 If the motor wiring diag...

Page 7: ...ntal run 10 of horizontal suction pipe 1 of vertical lift due to friction losses in the pipe If no water is produced within 10 minutes stop pump release all pressure remove priming plug refill and try...

Page 8: ...terminals together see Figure 14 Do not touch metal screwdriver blade or capacitor terminals If in doubt consult a quali fied electrician 4 Unscrew capacitor clamp and remove capacitor Do not disconn...

Page 9: ...arbon face of seal when passing it over threaded shaft end or shaft shoulder The carbon surface must remain clean or short seal life will result 9 Hold motor shaft with 7 16 open end wrench on shaft f...

Page 10: ...and re prime If receding water level of pump in well exceeds suction lift a deep well pump is needed 3 Impeller is plugged 3 Clean impeller see Maintenance 4 Check valve or foot valve is stuck 4 Repla...

Page 11: ...al for 5 8 Shaft U109 6A U109 6A U109 6A 7 Impeller C105 92PVB C105 92PBBB C105 214PFA Impeller Screw C30 51SS 8 Diffuser C1 258PCA C1 258PCA 8A Diffuser C1 274P 9 Screw 8 32 RH U30 869SS U30 869SS U3...

Page 12: ...reement call 9 am 5 pm Monday Saturday 1 800 827 6655 M A I N T E N A N C E A G R E E M E N T America s Repair Specialists REPAIRSERVICES America s Repair Specialists REPAIRSERVICES America s Repair S...

Reviews: