ELECTRICAL

Wiring Connections

Fire hazard.

Incorrect voltage can cause

a fire or seriously damage the motor and voids the war-
ranty. The supply voltage must be within ±10% of the
motor nameplate voltage.

NOTICE:

Dual-voltage motors are factory wired for

230 volts. If necessary, reconnect the motor for 115
volts, as shown. Do not alter the wiring in single volt-
age motors.
Install, ground, wire, and maintain your pump in com-
pliance with the National Electrical Code (NEC) or the
Canadian Electrical Code (CEC), as applicable, and
with all local codes and ordinances that apply. Consult
your local building inspector for code information.

Connection Procedure

1. Connect the ground wire first as shown in Figure 6.

The ground wire must be a solid copper wire at least
as large as the power supply wires.

2. There must be a solid metal connection between the

pressure switch and the motor for motor grounding
protection. If the pressure switch is not connected
to the motor, connect the green ground screw in the
switch to the green ground screw under the motor
end cover. Use a solid copper wire at least as large
as the power supply wires.

3. Connect the ground wire to a grounded lead in a ser-

vice panel, to a metal underground water pipe, to a
metal well casing at least ten feet (3M) long, or to a
ground electrode provided by the power company
or the hydro authority.

4. Connect the power supply wires to the pressure

switch as shown in Figure 6. 

5. Reinstall the pressure switch cover.

6

Figure 6 – Pressure switch wiring

Clamp the power cable to prevent strain 
on the terminal screws.

Connect the green (or bare copper)  ground wire 
to the green ground screw.

Motor wires 

connect here

.

3187 0398

Power supply wires

 connect here. 

230 Volt:

 Connect 2 hot wires (black and red)

here and cap the white (neutral) wire. It does
not matter which wire goes to which screw. 

115 Volt:

 Connect one hot wire (black or red)

to one of these screws (it doesn't matter 
which one). Connect the white (neutral) wire 
to the other screw. Cap any remaining 
black or red wires.

Distance in Feet From Motor to Meter

Branch*

0’

51’

101’

201’

201’

401’

Motor

Max.

Fuse

to

to

to

to

to

to

Horse-

Load

Rating

50’

100’

200’

300’

400’

500’

power

Volts

Amperes

Amps

Wire Size

1/2

115/230

10.4/5.2

15/15

14/14

14/14

10/14

10/14

6/14

6/12

TABLE I: WIRING CHART – Recommended Fusing and Wiring Data

* Time delayed fuses are recommended instead of fuses in any motor circuit.

Summary of Contents for CRAFTSMAN 390.2505

Page 1: ...perating Instructions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Installation Electrical Maintenance...

Page 2: ...rent supply agree with the motor wiring as shown on motor nameplate 10 The correct fusing and wiring sizing is essential to proper motor operation Use recommended fusing and wire size data in the manu...

Page 3: ...mation The strainer should not be too close to the bottom or sediment may clog it Before installing foot valve check to see that it works freely When using a foot valve a priming tee and a plug as sho...

Page 4: ...d possibly causing burns to persons handling pump Fill pump with water before starting Never run pump against closed dis charge To do so can boil water inside pump causing hazardous pressure in unit r...

Page 5: ...ike the one at right Dial Type Voltage Selector To change to 115 volts 1 Make sure power is off 2 Turn the dial counter clockwise until 115 shows in the dial window 3 Reinstall the Motor end cover 4 G...

Page 6: ...large as the power supply wires 3 Connect the ground wire to a grounded lead in a ser vice panel to a metal underground water pipe to a metal well casing at least ten feet 3M long or to a ground elect...

Page 7: ...w be removed 3 Carefully tap diffuser to remove from seal plate 4 Remove canopy from end of motor 5 Partially unscrew capacitor clamp move capacitor to one side 6 Hold motor shaft with 7 16 wrench on...

Page 8: ...ameter pointed tool into the nozzle and dislodge foreign material If it is not possible to push the obstruction through the nozzle or if the nozzle is damaged follow in structions above under Replacin...

Page 9: ...m buried in sand or mud Pump does not 1 Water level in well is lower than 1 A deep well jet pump may be needed over 20 ft to water deliver water to full estimated capacity Also 2 Steel piping if used...

Page 10: ...zzle No 43 11 U111 211T 1 Hose Barb 12 2 Pipe Plug 1 4 NPT Hex Head 13 N212 12P 1 Check Valve 14 1 Pipe Plug 1 8 NPT Square Head 15 N176 38A 1 Pump Body Assembly 16 4 Capscrew 3 8 16x1 1 4 Hex Head 17...

Page 11: ...6 U37 17GPT Nipple 1 4 x 1 1 2 37 U37 205P Tube AVC 38 U111 86T Compression Fitting Elbow 1 4 NPT 39 U111 100T Compression Fitting Straight 1 8 NPT Standard hardware item May be purchased locally Shal...

Page 12: ...r replacement parts you need Call 7 am 7 pm 7 days a week 1 800 366 PART 1 800 366 7278 For in home major brand repair service Call 24 hours a day 7 days a week 1 800 4 REPAIR 1 800 473 7247 For the l...

Reviews: