-21-
NOTE: When testing the magnetron, be sure to install the magnetron gasket in the
correct position and be sure that the gasket is in good condition.
Antenna
Gasket
Chassis
Filament
HIGH VOLTAGE
CAPACITOR
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to terminal.
Normal: Momentarily indicates
several ohms, and
then gradually returns
to infinite.
Normal: Infinite.
Normal: Continuity.
Abnormal: Infinite.
Normal: Infinite.
Abnormal: Continuity.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to case.
Measure the continuity (Forward).
(Ohm-meter scale: Rx10000)
Measure the continuity (Reverse).
(Ohm-meter scale: Rx10000)
HIGH VOLTAGE
DIODE
NOTE :
Some inexpensive meters
may indicate infinite
resistance in both direction.
COMPONENTS TEST
PROCEDURE
RESULTS