background image

LT-14296r2.0 20180515

5/15/18

Seametrics • 19026 72nd Avenue South • Kent, Washington 98032 • USA 

(P) 253.872.0284 • (F) 253.872.0285 • 1.800.975.8153 • seametrics.com 

Electrical Quick Start Guide

AC Power w/Pulse (A1X/A2X)

for: iMAG 4700r/ AG3000r 

Menu System

1.2345678

   

   100

TOTAL

CU FT

X1000

RATE

GPM

T UNIT

R UNIT SET  P DAMP

SET  4 SET 20 SET F

EXIT

TOTAL = GALLONS

PRESS       +       TO SET TOTAL

UNITS FOR DISPLAY

T UNIT R UNIT SET  P DAMP

SET  4 SET 20 SET F

EXIT

TOTAL:

        PRESS      TO CHANGE

GALLONS

FWD TOTAL

The HOME Screen

 displays flow volume, direction of  the flow total and flow RATE 

along with status conditions such as Empty Pipe. Two buttons below the LCD 

display are used to access menu screens for viewing and changing meter setup 

parameters. 

These two buttons are light sensors which can detect when a finger is covering 

them. Only three button touch actions are needed to control navigation 

through the menus, settings changes and back to the home screen. 

HORIZONTAL SCROLLING

Tap right-hand button to 

scroll horizontally through 

menu tabs or move 

horizontally within a tab 

dialog when applicable.

TAP

SELECT

: Tap left-hand button 

to change a highlighted item 

within a tab dialog.

TAP

ENTER/EXIT

: Hold left 

button while tapping right 

button once to enter or exit 

a tab dialog or to navigate 

between the HOME and  

other menu screens. 

+

HOLD TAP

All menu screens consist of two rows of tabs surrounding a dialog box that lets 

you view and change setup parameters. 

To enter the Menu System perform the 

hold and tap sequence.

+

HOLD TAP

T UNIT

View or change TOTAL 

volume units

R UNIT

View or change flow 

RATE units

Set P

View or change pulse 

output scaling

DAMP

View or change # of 

seconds for rolling 

average. 

(0=1 second,  
1=2 seconds, etc.)

EXIT

Return to HOME 

SCREEN or enter 

SUBMENU

T UNIT

R UNIT SET P DAMP

SET 4 SET 20 SET F

EXIT

TOTAL = GALLONS

PRESS       +       TO SET TOTAL

UNITS FOR DISPLAY

T UNIT

R UNIT

SET P DAMP

SET 4 SET 20 SET F

EXIT

FLOW RATE = GALLONS/MIN

PRESS       +       TO SET RATE

UNITS FOR DISPLAY

T UNIT R UNIT

SET P

DAMP

SET 4 SET 20 SET F

EXIT

00001.0

 GALLONS

PRESS       +       TO SET 

GALLONS TOTALIZED PER 

PULSE SENT OUT PULSE1

T UNIT

R UNIT SET P

DAMP

SET 4 SET 20 SET F

EXIT

DAMPING = 1

PRESS       +       TO SET 

DAMPING VALUE

T UNIT

R UNIT SET P DAMP

SET 4 SET 20 SET F

EXIT

PRESS       +       EXIT MENU 

AND RETURN TO FLOW

DISPLAY

The EXIT tab in the MAIN MENU has a second function. If you 
tap 

 five times, you will be redirected to a SUBMENU screen 

from which you can access additional options.

INFO

:   Meter model, serial number, firmware version