background image

• 

10

 •

RECONDITION TIME REMAINING XXX MINUTES

 – Recondition mode has started. The 

remaining time on the display counts down from 180 minutes.

RECONDITION SUCCESSFUL-START NORMAL CHARGING

 – Shows on display for  

60 seconds after a successful Recondition.

WARNING-CLAMPS REVERSED

 (No LED lit) – The output clamps are connected 

backwards to a battery.

ANALYZING 12V BATTERY

 (Green LED lit) – Plugged into the AC outlet, and when first 

correctly connected to 12V battery at 12V charge mode.

ANALYZING 24V BATTERY

 (Green LED lit) – Plugged into the AC outlet, and when first 

correctly connected to 24V battery at 24V charge mode.

CHARGING 12V – xx%

 (Green LED lit) – Plugged into the AC outlet and correctly 

connected to a discharged 12V battery at 12V charge mode.

CHARGING 24V – xx%

 (Green LED lit) – Plugged into the AC outlet and correctly 

connected to a discharged 24V battery at 24V charge mode.

FULLY CHARGED-AUTO MAINTAINING

 (Green LED pulsing) – Plugged into the AC 

outlet and correctly connected to a fully charged battery.

CHARGE ABORTED-BAD BATTERY

 (Green LED flashing) –

Circumstances that could cause an Abort situation during charging:

• The battery is severely sulfated or has a shorted cell and can’t reach a full charge.

• The battery is too large or there is a bank of batteries and it doesn’t reach full charge within 

a set time period.

Circumstances that could cause an Abort situation during maintain:

• The battery is severely sulfated or has a weak cell and will not hold a charge.

• There is a large draw on the battery and the charger has to supply its maximum maintain 

current for a 12 hour period to keep the battery at full charge.

• Recondition mode is unsuccessful.

BATTERY DISCONNECTED

 (No LED lit)

 –

 After charging has begun, the charger has lost 

its connection to the battery.

OFF

 (No LED lit) – During the charge process or Recondition process, press the button once to 

stop the charge or recondition. The display will show 

OFF

 and then 

SELECT CHARGE MODE

.

14.  MAINTENANCE INSTRUCTIONS

14.1 

Cleaning and user maintenance should not be done by children without supervision.

14.2 

After use and before performing maintenance, unplug and disconnect the battery charger 

(see sections 6, 7 and 8).

14.3 

Use a dry cloth to wipe all battery corrosion and other dirt or oil from the battery 

connectors, cords, and the charger case.

14.4 

Ensure that all of the charger components are in place and in good working condition, for 

example, the plastic boots on the battery clips.

14.5 

Servicing does not require opening the unit, as there are no user-serviceable parts.

14.6 

All other servicing should be performed by qualified service personnel.

14.7 

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or 

similarly qualified persons, in order to avoid a hazard.

15.  MOVING AND STORAGE INSTRUCTIONS

15.1 

Store the charger unplugged, in an upright position. The cord will still conduct electricity 

until it is unplugged from the outlet. 

15.2 

Store inside, in a cool, dry place.

15.3 

Do not store the connectors clipped together, on or around metal, or clipped to cables. 

15.4 

If the charger is moved around the shop or transported to another location, take care to 

avoid/prevent damage to the cords, connectors and charger. Failure to do so could result 

in personal injury or property damage.

Summary of Contents for SPI1224

Page 1: ...our charger safely and effectively Please read understand and follow these instructions and precautions carefully as this manual contains important safety and operating instructions The safety messages used throughout this manual contain a signal word a message and an icon The signal word indicates the level of the hazard in a situation Indicates an imminently hazardous situation which if not avoi...

Page 2: ...the extension cord are the same number size and shape as those of the plug on the charger That the extension cord is properly wired and in good electrical condition That the wire size is large enough for the AC ampere rating of the charger as specified in section 8 1 8 To reduce the risk of electric shock unplug the charger from the outlet before attempting any maintenance or cleaning Simply turni...

Page 3: ...water If acid enters your eye immediately flood the eye with cold running water for at least 10 minutes and get medical attention right away 2 10 If battery acid is accidentally swallowed drink milk the whites of eggs or water DO NOT induce vomiting Seek medical attention immediately 3 PREPARING TO CHARGE RISK OF CONTACT WITH BATTERY ACID BATTERY ACID IS A HIGHLY CORROSIVE SULFURIC ACID 3 1 If it ...

Page 4: ...ause injury 6 3 Check the polarity of the battery posts The POSITIVE POS P battery post usually has a larger diameter than the NEGATIVE NEG N post 6 4 Determine which post of the battery is grounded connected to the chassis The battery terminal not connected to the chassis has to be connected first The other connection is to be made to the chassis remote from the battery and fuel line See steps 6 ...

Page 5: ...t specially designed for marine use 8 GROUNDING AND AC POWER CORD CONNECTIONS RISK OF ELECTRIC SHOCK OR FIRE 8 1 This battery charger is for use on a nominal 230V 50Hz circuit The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances The plug pins must fit the receptacle outlet Do not use with an ungrounded system 8 2 DANGER N...

Page 6: ...ge has aborted See Aborted Charge section NOTE See Operating Instructions for a complete description of the charger modes 12 OPERATING INSTRUCTIONS WARNING This battery charger must be properly assembled in accordance with the assembly instructions before it is used The charger does not have an ON OFF switch The On and Off commands are controlled by plugging the SPI1224 into an AC electrical wall ...

Page 7: ...play will show RECONDITION TIME REMAINING XXX MINUTES If the recondition is successful the display will show RECONDITION SUCCESSFUL START NORMAL CHARGING If the recondition is unsuccessful the display will show CHARGE ABORTED BAD BATTERY and the GREEN LED will flash 5 When the battery is fully charged the GREEN LED will pulse 6 When charging is complete disconnect the AC cord from the supply mains...

Page 8: ...ctrical problems in the vehicle improper connections or other unanticipated conditions could cause excessive current draws As such occasionally monitoring your battery and the charging process is recommended FAN Your charger is equipped with a fan It is normal for the fan to run while the charger is charging Keep the area near the charger free of obstructions to allow the fan to operate efficientl...

Page 9: ...m maintain current for a 12 hour period to keep the battery at full charge Recondition mode is unsuccessful BATTERY DISCONNECTED No LED lit After charging has begun the charger has lost its connection to the battery OFF No LED lit During the charge process or Recondition process press the button once to stop the charge or recondition The display will show OFF and then SELECT CHARGE MODE 14 MAINTEN...

Page 10: ...C outlet Check power cord and extension cord for loose fitting plug I cannot select a language on the display Press the button for 5 seconds to select a language EN DE FR No problem this is normal Green LED is lit and the display shows ANALYZING 12V BATTERY or ANALYZING 24V BATTERY The charger needs to check the condition of the battery The green LED will be lit when the charger is checking the co...

Page 11: ... 12 ...