7.  FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE OF THE VEHICLE.

A SPARK NEAR THE BATTERY MAY CAUSE A 

BATTERY EXPLOSION. TO REDUCE THE RISK OF 

A SPARK NEAR THE BATTERY:

7.1 

Check the polarity of the battery posts. The 

POSITIVE (POS, P, +) battery post usually has a larger 

diameter than the NEGATIVE (NEG, N, -) post.

7.2 

Attach at least a 24-inch (61 cm) long 7 AWG (10 mm

2

) insulated battery cable to the 

NEGATIVE (NEG, N, -) battery post.

7.3 

Connect the POSITIVE (RED) charger connector to the POSITIVE (POS, P, +) post of the 

battery.

7.4 

Position yourself and the free end of the cable you previously attached to the NEGATIVE 

(NEG, N, -) battery post as far away from the battery as possible – then connect the 

NEGATIVE (BLACK) charger connector to the free end of the cable.

7.5 

Do not face the battery when making the final connection. 

7.6 

Connect charger AC supply cord to electrical outlet.

7.7 

When disconnecting the charger, always do so in the reverse order of the connecting 

procedure and break the first connection while as far away from the battery as practical.

7.8 

A marine (boat) battery must be removed and charged on shore. To charge it onboard 

requires equipment specially designed for marine use.

8.  GROUNDING AND AC POWER CORD CONNECTIONS

RISK OF ELECTRIC SHOCK OR FIRE.

8.1 

This battery charger is for use on a nominal 230V, 50Hz circuit. 

The plug must be plugged into an outlet that is properly installed 

and grounded in accordance with all local codes and ordinances. 

The plug pins must fit the receptacle (outlet). Do not use with an 

ungrounded system.

8.2 

DANGER

 Never alter the AC cord or plug provided – if it does not fit the outlet, have a 

proper outlet installed by a qualified electrician. An improper connection can result in a risk 

of an electric shock or electrocution. 

8.3  USING AN EXTENSION CORD

The use of an extension cord is not recommended. If you must use an extension cord, 

follow these guidelines:

• Pins on plug of extension cord must be the same number, size, and shape as those of 

plug on charger.

• Ensure that the extension cord is properly wired and in good electrical condition.
• Wire size must be large enough for the AC ampere rating of charger.

Recommended minimum AWG size for extension cord:

• 100 feet (30.5 meters) long or less – use an 16 gauge (1.31 mm

2

) extension cord.

• Over 100 feet (30.5 meters) long – use a 14 gauge (2.08 mm

2

) extension cord.

9.  ASSEMBLY INSTRUCTIONS

9.1 

Remove all cord wraps and uncoil the cables prior to using the battery charger. 

WARNING

WARNING

WARNING

WARNING

WARNING

Summary of Contents for SPI1224

Page 1: ...our charger safely and effectively Please read understand and follow these instructions and precautions carefully as this manual contains important safety and operating instructions The safety messages used throughout this manual contain a signal word a message and an icon The signal word indicates the level of the hazard in a situation Indicates an imminently hazardous situation which if not avoi...

Page 2: ...the extension cord are the same number size and shape as those of the plug on the charger That the extension cord is properly wired and in good electrical condition That the wire size is large enough for the AC ampere rating of the charger as specified in section 8 1 8 To reduce the risk of electric shock unplug the charger from the outlet before attempting any maintenance or cleaning Simply turni...

Page 3: ...water If acid enters your eye immediately flood the eye with cold running water for at least 10 minutes and get medical attention right away 2 10 If battery acid is accidentally swallowed drink milk the whites of eggs or water DO NOT induce vomiting Seek medical attention immediately 3 PREPARING TO CHARGE RISK OF CONTACT WITH BATTERY ACID BATTERY ACID IS A HIGHLY CORROSIVE SULFURIC ACID 3 1 If it ...

Page 4: ...ause injury 6 3 Check the polarity of the battery posts The POSITIVE POS P battery post usually has a larger diameter than the NEGATIVE NEG N post 6 4 Determine which post of the battery is grounded connected to the chassis The battery terminal not connected to the chassis has to be connected first The other connection is to be made to the chassis remote from the battery and fuel line See steps 6 ...

Page 5: ...t specially designed for marine use 8 GROUNDING AND AC POWER CORD CONNECTIONS RISK OF ELECTRIC SHOCK OR FIRE 8 1 This battery charger is for use on a nominal 230V 50Hz circuit The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances The plug pins must fit the receptacle outlet Do not use with an ungrounded system 8 2 DANGER N...

Page 6: ...ge has aborted See Aborted Charge section NOTE See Operating Instructions for a complete description of the charger modes 12 OPERATING INSTRUCTIONS WARNING This battery charger must be properly assembled in accordance with the assembly instructions before it is used The charger does not have an ON OFF switch The On and Off commands are controlled by plugging the SPI1224 into an AC electrical wall ...

Page 7: ...play will show RECONDITION TIME REMAINING XXX MINUTES If the recondition is successful the display will show RECONDITION SUCCESSFUL START NORMAL CHARGING If the recondition is unsuccessful the display will show CHARGE ABORTED BAD BATTERY and the GREEN LED will flash 5 When the battery is fully charged the GREEN LED will pulse 6 When charging is complete disconnect the AC cord from the supply mains...

Page 8: ...ctrical problems in the vehicle improper connections or other unanticipated conditions could cause excessive current draws As such occasionally monitoring your battery and the charging process is recommended FAN Your charger is equipped with a fan It is normal for the fan to run while the charger is charging Keep the area near the charger free of obstructions to allow the fan to operate efficientl...

Page 9: ...m maintain current for a 12 hour period to keep the battery at full charge Recondition mode is unsuccessful BATTERY DISCONNECTED No LED lit After charging has begun the charger has lost its connection to the battery OFF No LED lit During the charge process or Recondition process press the button once to stop the charge or recondition The display will show OFF and then SELECT CHARGE MODE 14 MAINTEN...

Page 10: ...C outlet Check power cord and extension cord for loose fitting plug I cannot select a language on the display Press the button for 5 seconds to select a language EN DE FR No problem this is normal Green LED is lit and the display shows ANALYZING 12V BATTERY or ANALYZING 24V BATTERY The charger needs to check the condition of the battery The green LED will be lit when the charger is checking the co...

Page 11: ... 12 ...