Page 1: ...rom sockets by the power cable 1 1 9 DO NOT use worn or damage leads plugs or connections Immediately replace or have repaired by a qualified Electrician This particular compressor is supplied without a mains plug Follow the instructions below regarding the fitting of an appropriate plug 1 2 MODEL SAC3203B3PH REQUIRES A 415V 3 PHASE SUPPLY AND MUST HAVE AN APPROPRIATE PLUG FITTED WARNING ELECTRICA...

Page 2: ...200ltr The pump features heavy duty fully cast cylinders capped by alloy heads for improved heat dissipation and long life Suitable for professional workshop applications The 2 cylinder pump is powered by a 415v 3ph 3 0hp motor A precision continuously welded receiver tank manufactured to meet Pressure Vessel Directive 2009 105 EC Fitted with fully automatic pressure cut out switch and receiver dr...

Page 3: ...by switching off the mains power or by pulling the plug out as the pressure relief will not then occur and motor damage may result upon restart When the compressor runs correctly and is stopped correctly there will be a A whistle of compressed air when the motor stops b A protracted whistle about 20 25 seconds when the compressor starts with no pressure in the tank 5 3 6 The output pressure is reg...

Page 4: ...lug and refill through the oil filler aperture Do not overfill Replace oil filler plug b Check the automatic cut out at max pressure and the automatic cut in at 2bar below WARNING Never mix different oils and DO NOT use non detergent low quality oils as the compressor may be damaged WARNING Dispose of waste oil only in accordance with local authority requirements 6 6 OPERATIONS TO BE CARRIED OUT E...

Page 5: ...IMMEDIATELY 4A Motor stops and will not restart Thermal cut out has operated Allow unit to cool for 30 minutes before restarting 4B Motor stops and will not restart Supply has tripped Press trip reset and restart unit If repeated tripping occurs replace the check valve or contact authorised Service Agent 5 Compressor stops and does not restart Motor failure Contact Authorised Service Agent 6A Comp...

Page 6: ...Original Language Version SAC3203B3PH Issue No 1 27 10 14 Jack Sealey Limited ...