background image

fig.10  

Located on tank, see also 7.2

NOTE:

 It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of this product. 

WARRANTY: 

Guarantee is 24 months from purchase date, proof of which will be required for any claim. 

INFORMATION:

 For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group, 

Kempson Way, Suffolk Business Park

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

W e b

email

FAULT

POSSIBLE CAUSE

REMEDY

1A)  Pressure drop in the tank

Air leaks at connections

Run  compressor  to  max.  pressure,  switch  off.                   

Brush soap solution over connections and look for 

bubbles. Tighten connections showing leaks. 

If problem persists contact Authorised Service Agent

1B)  Pressure drop in the tank

Air leaks from safety valve

It should be replaced, unless leaking at a joint 

which can be sealed.

1C)  Pressure drop in the tank

Air leaks from cylinder head gasket

Check tightness of head bolts. If leak continues 

contact authorised Service Agent

2)  Pressure switch valve leaks when 

     compressor is idle

Non-return valve seal defective

Empty the air tank. Referring to fig.10, remove the 

non-return valve cap (3), spring (2) and seal (1). 

Clean the seal and its seat, or if necessary replace 

the seal

3)  Air leaks from tank body or tank welds

Internal corrosion caused by infrequent tank 

draining or non permitted modifications to tank

Tank could rupture or explode. Cannot be repaired 

DISCONTINUE USE IMMEDIATELY

4A)  Motor stops and will not restart

Thermal cut out has operated

Allow unit to cool for 30 minutes before restarting

4B)  Motor stops and will not restart

Supply has tripped

Press trip reset and restart unit. If repeated tripping 

occurs replace the check valve or contact 

authorised Service Agent

5)  Compressor stops and does not restart

Motor failure

Contact Authorised Service Agent

6A)   Compressor does not stop at max. pressure

Pressure switch fault

Contact Authorised Service Agent

6B)   Compressor does not stop at max. pressure

Filter clogged

Head gasket or valve fault

Replace filter element.

Contact Authorised Service Agent

7)  Compressor noisy with metallic knock

Bearing or piston damage

Contact Authorised Service Agent

8)  Excessive moisture in discharged air

High humidity environment

Drain tank after each use

Parts support is available for this product. To obtain a parts listing and/or diagram, 

please log on to www.sealey.co.uk, email [email protected] or telephone 01284 757500.

7.  TROUBLESHOOTING

Original Language Version

SAC3203B3PH     Issue No: 1 - 27/10/14

© Jack Sealey Limited 

 

Environmental Protection

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be 

sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.

When the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable)

into approved containers and dispose of the product and the fluids according to local regulations.

WEEE Regulations

Dispose of this product at the end of its working life in compliance with the EU Directive on 

Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed

of in an environmentally protective way. Contact your local solid waste authority for recycling information.

Summary of Contents for SAC3203B3PH

Page 1: ...rom sockets by the power cable 1 1 9 DO NOT use worn or damage leads plugs or connections Immediately replace or have repaired by a qualified Electrician This particular compressor is supplied without a mains plug Follow the instructions below regarding the fitting of an appropriate plug 1 2 MODEL SAC3203B3PH REQUIRES A 415V 3 PHASE SUPPLY AND MUST HAVE AN APPROPRIATE PLUG FITTED WARNING ELECTRICA...

Page 2: ...200ltr The pump features heavy duty fully cast cylinders capped by alloy heads for improved heat dissipation and long life Suitable for professional workshop applications The 2 cylinder pump is powered by a 415v 3ph 3 0hp motor A precision continuously welded receiver tank manufactured to meet Pressure Vessel Directive 2009 105 EC Fitted with fully automatic pressure cut out switch and receiver dr...

Page 3: ...by switching off the mains power or by pulling the plug out as the pressure relief will not then occur and motor damage may result upon restart When the compressor runs correctly and is stopped correctly there will be a A whistle of compressed air when the motor stops b A protracted whistle about 20 25 seconds when the compressor starts with no pressure in the tank 5 3 6 The output pressure is reg...

Page 4: ...lug and refill through the oil filler aperture Do not overfill Replace oil filler plug b Check the automatic cut out at max pressure and the automatic cut in at 2bar below WARNING Never mix different oils and DO NOT use non detergent low quality oils as the compressor may be damaged WARNING Dispose of waste oil only in accordance with local authority requirements 6 6 OPERATIONS TO BE CARRIED OUT E...

Page 5: ...IMMEDIATELY 4A Motor stops and will not restart Thermal cut out has operated Allow unit to cool for 30 minutes before restarting 4B Motor stops and will not restart Supply has tripped Press trip reset and restart unit If repeated tripping occurs replace the check valve or contact authorised Service Agent 5 Compressor stops and does not restart Motor failure Contact Authorised Service Agent 6A Comp...

Page 6: ...Original Language Version SAC3203B3PH Issue No 1 27 10 14 Jack Sealey Limited ...

Reviews: